Venting installation instructions – Desa V)CD36RN User Manual

Page 20

background image

www.desatech.com

116035-01E

0

PARTS LIST FOR vENTING KITS
AND COMPONENTS

DESA (5"/8") Pipe & vent Kits
Number Description
P58-6

6" Section Double Wall Pipe,

Galv.

P58-1

1" Section Double Wall Pipe,

Galv.

P58-4

4" Section Double Wall Pipe, Galv.

P58-36

36" Section Double Wall Pipe, Galv.

P58-48

48" Section Double Wall Pipe,

Galv.

PA58-71 Adjustable 7"-1" Section Double

Wall Pipe, Galv.

E58-45

45° Elbow, Galv.

E58-90

90° Elbow, Galv.

VENTING INSTALLATION

INSTRUCTIONS

Continued

Number Description
VKG-58 Ground Floor Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

Horizontal Square Termination,

16 Screws)

VKB-58 Basement Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

Horizontal Square Termination,

4' Pipe, 90° Elbow, 0 Screws)

VKS-58 Snorkel Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

36" Snorkel Termination, 4' Pipe,

1' Pipe, 90° Elbow, 6 Screws)

VKR-58 R o o f Ve n t K i t , G a l v a n i z e d

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Flue Restrictor,

Vertical High Wind Termination,

' Pipe, 4' Pipe, Wall Firestop,

Storm Collar, Roof Flashing

[0/1 - 6/1], 6 Screws)

VKC-58 Corner Vent Kit, Galvanized

(Includes 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

Horizontal Termination, 6" Pipe,

90° Elbow, 18 Screws)

HHTK-58 High Wind Round Horizontal

Termination Kit (Includes Round

Termination, Wall Firestop, 45°

Elbow)

HHT-58 High Wind Round Horizontal

Termination Kit, Galv.

HTS-58 Horizontal Square Termination, Galv.
HTKS-58 Horizontal Square Termination Kit

(Includes: Square Termination,

Wall Firestop, 45° Elbow)

VT-58

Vertical Round Termination, Galv.

ST-58-14 14" Snorkel Termination, Galv.
ST-58-36 36" Snorkel Termination, Galv.
SC-58

Storm Collar, Galv.

WF-58

Wall Firestop, Galv.

RF-58-6 Roof Flashing - 0 to 6/1 Pitch,

Galv.

RF-58-1 Roof Flashing - 6/1 to 1/1 Pitch,

Galv.

VR-58

Vertical Restrictor, Galv.

S-58

Vinyl Siding Standoff, Galv.

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing -

For use with HTS-58

RF-58

Flat Roof Flashing

OSR58-30 30° Offset Return

Figure 33 - Vertical Venting

Configuration with No Horizontal Run

(Model (V)CD36T with Vertical Round High

Wind Termination)

vertical venting

V = 40' Max.

Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination cap.

Note: Install an
OSR58-30 30°
offset return
with WS-58 wall
strap supports
as necessary
to maintain 1"
Clearance to all
horizontal wood
frame members.

WS-5 8