beautypg.com

6] setting the communications environments – Denso BHT-6000 User Manual

Page 63

background image

48

[4.6]

Setting the communications environments

After the BHT-6000 is initialized, the interface port and communications parameters
are set as listed in the default table below. Do not access them unless necessary.

Interface port

Communications protocol

Communications parameters
for the optical interface port

TRANSMIT SPEED

9600 bps

PULSE WIDTH

1.63 µs

(Output pulse width of IR beam)

PROTOCOL
(Protocol options)

OPT (Optical interface port)

BHT-protocol

Defaults

SERIAL No. ON: Adds serial numbers to

data blocks.

H. PARITY ON:

Adds a horizontal parity.

LINKUP TIME:

30 seconds

FIELD SPACE:

Ignore

Listed below are the default communications parameters for the direct-connect inter-
face

Defaults

Communications parameters for
the direct-connect interface port

TRANSMIT SPEED

19200 bps

PARITY BIT

None

DATA BIT

8 bits

(Character length)

STOP BIT

1 bit

PROTOCOL
(Protocol options)

SERIAL No. ON: Adds serial numbers to

data blocks.

H. PARITY ON:

Adds a horizontal parity.

LINKUP TIME:

30 seconds

FIELD SPACE:

Ignore