3 interfacing with the host computer, Interfacing with the host computer – Denso BHT-6000 User Manual
Page 153
138
5.4.3 Interfacing with the Host Computer
(1)
Power on the host computer and start up the MS-DOS.
(2)
Turn on the power switch of the CU-6000.
(3)
Make sure that the BHT-6000 is turned off, then put it on the CU-6000.
(4)
Power on the BHT-6000 and run System Mode. Set the communications environ-
ments (communications protocol, interface port, communications parameters,
and protocol options).
Regarding the communications protocol: When using Ir-Transfer Utility C on the
host computer, select the BHT-Ir protocol; when using Transfer Utility, select the
BHT-protocol.
Regarding the interface port: Select the optical interface port.
(5)
On the host computer, initiate a communications program (e.g., Ir-Transfer Utility
C, Transfer Utility, or equivalent).
(6)
To transfer data stored in the BHT-6000 to the host computer, select "3: UPLOAD"
on the SYSTEM MENU in System Mode. To transfer data from the host computer
to the BHT-6000, select "2: DOWNLOAD." (For details, refer to Chapter 2, Section
2.5.)
The BHT-6000 and the host computer will start communications with each other
via the CU-6000. (On the CU-6001, the DATA LED will come on upon start of
communications. After completion of communications, the LED will go off.)
(7)
Power off the BHT-6000, CU-6000, and the host computer.