Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Anti-Tip Bracket Installation
To reduce the risk of tipping the appliance by abnormal usage
or improper door loading, the appliance must be secured by
properly installing the anti-tip device packed

\with the appliance.
The paper template supplied with the range should be used to

indicate the locations of screws that fix the anti-tip bracket to

adjacent wall.

Fold the paper template along the lower thick black line and

hold it against the floor and wall in the position you intend the range to be

fitted. (See Figure 3). The thick black lines are the same width as the

range.
Mark the centers of the two fixing holes with a pencil on the wall.
If you are fixing to a timber skirting board, make two pilot holes with a

center-punch before screwing the bracket to the wall. If you are fixing to
a plastered/brick/stone wall, use a masonry drill bit and the anchors

supplied.

Finally, screw the anti-tip bracket into the wall and insert the tip of the
bracket to the slot located on the lower rear part of the range

(See Figure 4).

Gas Connection

Gas connection must be made in accordance with local codes
or in absence of local codes, with the National Fuel Gas Code,

ANSI Z223.1-Latest Edition.

Connect gas supply to regulator using a flexible connector, as
shown in Figure 5. Pressure regulator supplied with this range
has a 1/2-inch NPT female connection.

A manual shutoff, not supplied with this range, must be installed

in an accessible location outside of the range.
Use joint compound that is resistant to action of natural or
propane gas on all male pipe threads.
Use supplied pressure regulator only.
Do not over tighten gas fitting when attaching to pressure
regulator. Overtightening may crack regulator.

Appliance and individual shutoff valve must be disconnected from the gas

supply piping system during any pressure testing of that system at test
pressures In excess of 1/2 psi (3.5 kPa).

Appliance must be isolated from gas supply piping system by loosening manual shutoff

valve during any pressure testing of the gas supply piping system at test pressures

equal to or less then 1/2 psi (3.5 kPa).
Gas supply pressure for checking regulator setting must be at least 1-inch water column
above manifold pressure shown on nameplate.

After final gas connection is made, turn on manual gas valve and test all connections in

gas supply piping and range for gas leaks.

Fie. 5