Avanti GR-20 User Manual
Page 13
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
The oven door glass (DGR-21A) should be cleaned regularly with a non-abrasive liquid cleaner. Rinse
with a damp cloth and then a dry one. The enameled and metal parts of the oven should be cleaned with
hot water and suitable liquid enamel cleaner.
Do not use harsh abrasive cleaners on the enameled panels.
> Cleaning your Oven
> Cleaning of Knobs and Control Panel
•
Pull forward on the knobs to remove them.
•
Wash in a water solution with a mild detergent mix. Do not use an abrasive cleaner or abrasive
action. Abrasive action will scratch away the knob markings.
•
The control panel should be cleaned by using a damp cloth with mild detergent. Never rinse with
an abrasive cleaner or use abrasive action.
> Cleaning of Utensil Supports, Cooktop, Backquard and Surface Burners
•
utensil supports are made of enamel coated steel.
•
They can be cleaned at the sink with detergent or soap-filled scouring pads. They can also be put
in a dishwasher.
•
The cook top and backguard are also made of enameled-coated steel. They should be cleaned
with hot water and suitable liquid enamel cleaner.
•
The aluminum burner rings may be damaged if soaked or put into a dishwasher. They should be
washed with a fine soapy wire wool.
•
The burner caps are made of enameled sheet. They can be cleaned in the same manner as
utensil supports. It is very important that the burner be dry before replacing it in the range. A wet
burner will not allow the gas ignite properly.
Converting Gas Type
This range arrives from factory, adjusted for use with Natural Gas. The setting is indicated on
the nameplate. It is important that the range is converted, if the factory adjusted gas type is not
desired.
To avoid electric shock that can cause personal injury or death, disconnect the appliance from
the electric outlet before servicing.
> Conversion of Pressure Regulator
The gas pressure regulator must be set for the type of gas being
used. The inlet pressure of the gas supply shall be in accordance
with the nominal inlet pressure of the regulator used on the range
or 1/2 psi (3.5 kPa) pressure maximum. On the factory setting for
Natural Gas operation, the pressure regulator will regulate the
pressure to 6 inches water column pressure. When set for LP-
Propane gas operation, it will regulate the pressure to 10 inches
water column pressure.
To change the pressure regulator setting:
• Unplug the main supply cord of the range.
' • Unscrew the cap on the pressure regulator._________________________
• Lift out cap and turn it over. If set for LP-Propane gas operation, the cap
must show "LP". If set for Natural Gas operation, the cap must show none.
13