Conversion of Burner Valves
• Unplug the main supply cord of the range.
• Remove burner control knobs from range by pulling them out.
• Remove the screws on the front surface of control panel.
• Remove two screws located on the bottom surface of control
panel.
• Pull out the control panel.
• Using a small screwdriver, loosen or tighten the screws located
on each valve. If set for LP-Propane gas operation, the screws
must be tightened fully. In the factory setting for Natural Gas
operation, the screws must be loosened by turning them
counterclockwise 3/4 turn.
• Replace the control panel and screws.
• Replace the control knobs. (See Figure 15)
Conversion of Surface Burners
•
Unplug the main supply cord of the range.
•
Remove the rings of surface burners.
•
Pull up the burner rings with their caps and unscrew the orifices
using a 7mm-spanner socket.
•
Use orifices located on the information card in a plastic bag at
lower rear side of the range. In order to choose the required orifice
for particular burner and gas type; see the mark located on orifices
and look at the information card.
•
Screw each orifice to proper matching burner.
•
Place the burner rings to their original locations. Be careful that the
burner rings are level with the surface of the main top.
•
Keep the remaining orifices in their plastic bag for future use. (See Figure 16 and
Table 1)
BURNERS
1 LP GAS
NATURAL GAS
RAPID
i
0.92
1.40
SEMl-RAPlD
i 0.65
0.97
SIMMER
! 0.50
0.75
OVEN
i 0.90
1.32
BROILER*
! 0.90
1.32
Table 1 - Marks on orifices
•MODEL DGR-21A ONLY
14