beautypg.com

Ac test loads and waveforms, Capacitance, Thermal resistance – Cypress CY7C1332AV25 User Manual

Page 14

background image

PRELIMINARY

CY7C1330AV25
CY7C1332AV25

Document No: 001-07844 Rev. *A

Page 14 of 19

AC Test Loads and Waveforms

Notes:

17. Tested initially and after any design or process change that may affect these parameters.
18. Unless otherwise noted, test conditions assume signal transition time of 2 V/ns, timing reference levels of 0.75V, V

REF

= 0.75V, RQ = 250

Ω, V

DDQ

= 1.5V, input

pulse levels of 0.25V to 1.25V, and output loading of the specified I

OL

/I

OH

and load capacitance shown in (a) of AC Test Loads.

Capacitance

[17]

Parameter

Description

Test Conditions

Max.

Unit

C

IN

Input

Capacitance

T

A

= 25°C, f = 1 MHz,

V

DD

= 2.5V

V

DDQ

= 1.5V

5

pF

C

CLK

Clock Input Capacitance

6

pF

C

I/O

Input/Output Capacitance

7

pF

Thermal Resistance

[17]

Parameter

Description

Test Conditions

BGA Typ.

Unit

Θ

JA

Thermal Resistance
(Junction to Ambient)

Still Air, soldered on a 4.25 x 1.125 inch, 4-layer printed
circuit board

19.7

°C/W

Θ

JC

Thermal Resistance
(Junction to Case)

6.0

°C/W

1.25V

0.25V

R = 50

5 pF

ALL INPUT PULSES

Device

R

L

= 50

Z

0

= 50

V

REF

= 0.75V

V

REF

= 0.75V

[18]

0.75V

Under
Test

0.75V

Device
Under
Test

OUTPUT

0.75V

V

REF

V

REF

OUTPUT

ZQ

ZQ

(a)

Slew Rate = 2 V/ns

RQ =
250

(b)

RQ =
250

[+] Feedback