Troubleshooting LAN Emulation

Troubleshooting

4.

Check ILMI, UNI routes, and PVCs (if applicable).

If using SVCs, use

show uniroute

to check whether static UNI routes are correct and whether

dynamic UNI routes are established and correct. If dynamic routes are incorrect or missing, try
creating static routes instead.

If using PVCs, use

show pvc

to check whether PVCs connect the correct resources through the

correct ports.

If using PVCs, use show

ipatmpvc

to check whether local switch clients are mapped to the correct

end node IP addresses.

5.

If working through these questions does not solve the problem, contact Cabletron Systems Customer
Service. (See Appendix C, "Technical Support." )

5.2

TROUBLESHOOTING LAN EMULATION

You have configured an Emulated LAN and your network applications are not working. Use these questions and tests
to help determine the cause of the problem.

1.

Check for connectivity. Try pinging between end nodes. Ping from the SmartCell 6A000
(using

start ping

) to its end nodes. If you cannot ping, check physical connectivity

(disconnected cable, and so on).

2.

Check IP routes and addresses.

Use the

show route

command to check the SmartCell 6A000 route table.

-

Are the destination addresses correct for the specified gateways?

-

Are there any routing loops?

-

Are one or more of the destination addresses mapped to the wrong subnet?

Use

show client

to check the SmartCell 6A000 local ELAN client.

-

— Does the client have the correct IP address?

-

— Is the subnet correct?

-

— Is the ATM address correct?

-

— Is the server type correct?

Check end node configurations.

-

Are end nodes configured correctly?

3.

If the ELAN spans multiple switches, check the following:

Is the LECS address correct on all switches?

Can all switches reach the switch providing LECS support?

If using the Well Known LECS Address, are all switches correctly mapped?

4.

Check the LECS database.

Use

show lecselan

to check the names and numbers of ELANs.

-

Are ELAN names correct?

-

Is the ATM address of the LES correct?