beautypg.com

1 iisp routing, Creating iisp routes, Iisp routing -4 – Cabletron Systems SmartCell 6A000 User Manual

Page 38

background image

4-4 SmartCell 6A000 User Guide

Setting Up Routes

Switch Administration

4.3.1

IISP Routing

IISP routing connects two or more switches (or other devices). Through SVCs, IISP routes create user-transparent links
over which IP over ATM and LANE members can operate with each other and their respective support servers (ARP
server, LECS, LES, and so on). For example, if a VLAN spans two or more switches, all nodes in the VLAN can
communicate with the ARP server and with each other if the switches are connected using IISP routes.

Creating IISP Routes

Use the

add iisproute

command to create IISP routes. IISP routes are defined on each switch by the port number

through which the route exists and the netprefix of the switch at the opposite end.

For example, to set up an IISP route between port A4 on switch SW1 and port A4 of SW2, you would perform the
following steps.

1.

Physically connect port A4 of switch SW1 to port A4 of switch SW2.

2.

If the netprefixes of port A4 on SW1 and port A4 on SW2 are not already known, enter the

show

netprefix

command on each switch.

For switch SW1, enter:

SmartCell ZX # show netprefix a4

Port# NetPrefix

============================================================================

A4 39:00:00:00:00:00:00:00:00:00:14:41:80

SmartCell ZX #

For switch SW2, enter

SmartCell ZX # show netprefix a4

Port# NetPrefix

============================================================================

A4 39:00:00:00:00:00:00:00:00:00:14:47:80

SmartCell ZX #

3.

Enter the

add iisproute

command on each switch.

From SW1, enter

SmartCell ZX # add iisproute

ATMAdress() : 39:00:00:00:00:00:00:00:00:00:14:47:80

PortNumber(A1) :a4

Metric(1) :

SmartCell ZX #

From SW2, enter

SmartCell ZX # add iisproute

ATMAdress() : 39:00:00:00:00:00:00:00:00:00:14:41:80

PortNumber(A1) : A4

Metric(1) :

SmartCell ZX #

4.

To see if the IISP routes exist, use the

show iisproute

command on each switch.

From SW1, enter

SmartCell ZX # show iisproute

Entry# Port# Metric Len Address

============================================================================

0 A4 1 104 39:00:00:00:00:00:00:00:00:00:14:47:80

SmartCell ZX #