2 point-to-multipoint pvcs, Point-to-multipoint pvcs -15 – Cabletron Systems SmartCell 6A000 User Manual
Page 49

SmartCell 6A000 User Guide 4-15
Switch Administration
Setting Up PVC Connections
3.
Use
add ipatmpvc
to associate the end node's IP address with the PVC.
SmartCell ZX # add ipatmpvc
ClientNumber(0) : 2
DestinationIP() : 10.1.1.22 DestinationVPI(0) : DestinationVCI(33) : 100 SmartCell ZX # 4. Connect the end node to port A1 of the SmartCell 6A000. 5. Configure the end node with IP address 10.1.1.22, subnet mask 255.0.0.0, and VPI/VCI pair = 0/100. 4.5.2 Point-to-Multipoint PVCs Instructions in this section describe how to set up a point-to-multipoint connection through your SmartCell 6A000. Example: Create a point-to-multipoint connection between a broadcasting workstation on port A1 and three other 1. Use add trafficdescriptor to create a backward traffic descriptor with AAL Type = null. This assures that traffic on the PVC is one way only. SmartCell ZX # add trafficdescriptor TrafficType(UBR) : TrafficDescriptorType(8) : PCRCLP01(0) : PCRCLP0(0) : SCRCLP01(0) : SCRCLP0(0) : MBSCLP01(0) : MBSCLP0(0) : QOSClass(1) : AALType(5) : 0 SmartCell ZX # 2. Use show trafficdescriptor to obtain the new traffic descriptor index number. SmartCell ZX # show trafficdescriptor TD# Traff Desc QoS Peak Cell Rate Sust Cell Rate Max Burst Size Aal VC Type Type (Kb/s) (Kb/s) (Kb) Type Type CLP_0 CLP_0+1 CLP_0 CLP_0+1 CLP_0 CLP_0+1 ============================================================================ 1 UBR 8 4 0 34 0 0 0 0 5 PVC 2 NRTVBR 2 1 0 1372 0 0 0 0 5 PVC 3 UBR 8 1 0 0 0 0 0 0 5 PVC 4 UBR 8 1 0 0 0 0 0 0 0 PVC 4155 UBR 8 0 0 138889 0 0 0 0 5 SVC 4158 UBR 8 0 0 353 0 0 0 0 5 SVC 4162 UBR 8 0 0 353 0 0 0 0 5 SVC 4180 UBR 8 0 0 353 0 0 0 0 5 SVC SmartCell ZX # In the example above, traffic descriptor # 4 (left column) has AALType 0 ( null ).
workstations connected to ports B2, B3, and C1.