Cabletron Systems SmartCell 6A000 User Manual
Page 51
SmartCell 6A000 User Guide 4-17
Switch Administration
Setting Up PVC Connections
For example, change VCCMask indexed combination zero (0) from VPI = 0 bits and VCI = 12 bits to
VPI = 3 bits and VCI = 9 bits.
1.
Use
set vccmask
to change the VPI/VCI values to 3/9.
SmartCell ZX # set vccmask
MaskIndex(0) :
VPIShift(0) : 3 VCIShift(12) : 9 SmartCell ZX # 2. Use the show vccmask command to see the new VPI/VCI combination. SmartCell ZX # show vccmask MaskIndex VpiShift VciShift (In bits) (In bits) ============================================================================ 0 3 9 1 2 10 2 4 8 3 6 6 SmartCell ZX # 3. Use the set portconfig command to reconfigure a port to use the new values for VPI and VCI. For example, to set up a PVC on port A1 using the new VPI/VCI bit ranges (3/9), enter SmartCell ZX # set portconfig a1 MaxVPIBits(0) : 3 MaxVCIBits(12) : 9 InterfaceAddressType(PRIVATE) : Trying to change VPI/VCI bits. This might affect existing PVCs. Proceed any way? Confirm(y/n)?:y SmartCell ZX # 4. Use show portconfig to see the change to port A1. SmartCell ZX # show portconfig a1 Port A1 Configuration ============================================================================ Port Id : A1 Port Admin State : ACTIVE Port QSAAL State : UP Port Operational State : UP Transmission Type : STS-3c Media Type : MMF Address Type : PRIVATE Active VPI Bits : 2 Active VCI Bits : 10 Configured VPI Bits : 3 Configured VCI Bits : 9 Current VPI Bits : 2 Current VCI Bits : 10 Current In Use VCCs : 3 Current Max VCCs : 4096 SmartCell ZX # PVCs can be configured for port A1 using VPI values from 0 to 7 and VCI values from 0 to 511. Note Do not set the VCI part of the VCCMask to fewer than 5 bits.