beautypg.com

Cabletron Systems SmartCell 6A000 User Manual

Page 51

background image

SmartCell 6A000 User Guide 4-17

Switch Administration

Setting Up PVC Connections

For example, change VCCMask indexed combination zero (0) from VPI = 0 bits and VCI = 12 bits to

VPI = 3 bits and VCI = 9 bits.

1.

Use

set vccmask

to change the VPI/VCI values to 3/9.

SmartCell ZX # set vccmask

MaskIndex(0) :

VPIShift(0) : 3

VCIShift(12) : 9

SmartCell ZX #

2.

Use the

show vccmask

command to see the new VPI/VCI combination.

SmartCell ZX # show vccmask

MaskIndex VpiShift VciShift

(In bits) (In bits)

============================================================================

0 3 9

1 2 10

2 4 8

3 6 6

SmartCell ZX #

3.

Use the

set portconfig

command to reconfigure a port to use the new values for VPI and VCI. For

example, to set up a PVC on port A1 using the new VPI/VCI bit ranges (3/9), enter

SmartCell ZX # set portconfig a1

MaxVPIBits(0) : 3

MaxVCIBits(12) : 9

InterfaceAddressType(PRIVATE) :

Trying to change VPI/VCI bits. This might affect existing PVCs.

Proceed any way?

Confirm(y/n)?:y

SmartCell ZX #

4.

Use

show portconfig

to see the change to port A1.

SmartCell ZX # show portconfig a1

Port A1 Configuration

============================================================================

Port Id : A1

Port Admin State : ACTIVE

Port QSAAL State : UP

Port Operational State : UP

Transmission Type : STS-3c

Media Type : MMF

Address Type : PRIVATE

Active VPI Bits : 2

Active VCI Bits : 10

Configured VPI Bits : 3

Configured VCI Bits : 9

Current VPI Bits : 2

Current VCI Bits : 10

Current In Use VCCs : 3

Current Max VCCs : 4096

SmartCell ZX #

PVCs can be configured for port A1 using VPI values from 0 to 7 and VCI values from 0 to 511.

Note

Do not set the VCI part of the VCCMask to fewer than 5 bits.