Compaq LA36 User Manual
Page 127
C-13
Command Sets
Function
Command
Miscellaneous
Mnemonic Function
Command
Remarks
BEL
Bell
0/7
C0 Control Code
DECSCL Select Conformance
CSI Ps1 " p
Ps = 0: reset - native level
Level
Ps = 71: reset - DEC PPL1
Ps = 72: reset - DEC PPL2
DECSTR Soft Terminal Reset
CSI ! p
Reset to initial state
RIS
Reset to Initial State
ESC c
Reset to initial state
DECIPEM IBM Proprinter
CSI ? 58 h
Deprecated function
Protocol Mode
CSI ? 58 l
ROCS
Return from Other
ESC % @
Return to DEC PPL2 mode
Coding System
SOCS
Select Other Coding
ESC % =
IBM Proprinter Protocol
System
ESC % SP 2
Epson Protocol
CRM
Control Representation CSI 3 h
Print hex representation for all
Mode
CSI 3 l
characters
Reset
DECASFC Automatic Sheet
CSI Ps ! v
Ps = 0: No change
Feeder Control
Ps = n: Tray n (reserved)
Ps = 4 : Tractor feeding
Ps = 99: Manual feed
DECSITF Select Input Tray
CSI Ps1 ; Ps2
Ps1 = 0: Disable all composite
input
Failover
; . . . ; Psn SP w trays
Ps1 = n: Define composite tray n
Ps2Psn = n: Add tray n to the
composite definition
DECUPM Unidirectional Print
CSI ? 41 h
Set unidirectional print mode
Mode
CSI ? 41 l
Reset unidirectional print mode
SnC1R
C1 Transmit
ESC SP 6
Process 7-bit, drop 8th bit
/DEC*C1 /Receive
ESC SP 7
Process 7-bit and 8-bit
ESC SP F
Transmit 8-bit as 7-bit equivalents
ESC SP G
Transmit 8-bit (not supported)