beautypg.com

USL LSS-100 User Manual

Page 17

background image

LSS−100P Installation & Operation Manual

17

The LSS-100P commands and typical responses are shown in figure 19. Note that many of these
commands are commonly used in scripts (described previously), and the lss100.sys.script_run command
can be used to start script execution.

Command

Response

Description

lss100.sys.auditorium

1

Returns the auditorium number
entered on the configuration
page.

lss100.sys.cct

6255.250284

Returns the correlated color
temperature.

lss100.sys.cdm2

405.151492

Returns the luminance in
candelas per square meter

lss100.sys.comments

Conference Room

Returns the auditorium
comments entered on the
configuration page.

lss100.sys.ftl

118.332596

Returns the measured luminance
in foot-Lamberts

lss100.sys.spl

83.239520

Returns the measured sound
pressure level in dBc

lss100.sys.temperature

29.2\t84.

Returns the internal
temperature in degrees C and
degrees F (separated by tab).

lss100.sys.theater_name

USL San Luis Obispo Returns the theater name

entered on the configuration
page.

lss100.sys.theater_number

1

Returns the theater number
entered on the configuration
page.

lss100.sys.ver

C\t130522\t120530

Returns the circuit board
version, the firmware version,
and the bootloader versions,
separated by tab.

lss100.sys.xy

0.314743\t0.353419 Returns the chromaticity as x tab

y.

lss100.sys.capture_spl|SPL Center Low|81.2|83.2

83.239520

Instructs the LSS-100P to capture
the current SPL to its log. The
parameters are description, min,
and max. Returns the current
SPL in dBc.

lss100.sys.capture_fl|Luminance|13|15

14.1234

Instructs the LSS-100P to capture
the luminance (measured in fL)
to its log. The parameters are
description, min, and max.

lss100.sys.capture_cdm2|Luminance|47|49

48.4321

Instructs the LSS-100P to capture
the luminance (measured in
cd/m

2

) to its log. The parameters

are description, min, and max.