beautypg.com

Operation in general encoding, Operation in general, Encoding – TeeJet LH 3000 User Manual

Page 8

background image

LH 3000

OPERATING MANUAL

8

LH A

GRO

OPERATION IN GENERAL

All encoding values (basic data) for the calculations are divided in 14 values (1 –
14).
Th encoding values will appear by pressing the “SYSTEM”-key after which the
numerical keyboard will be lit and the values can be encoded.
By repeated press on the “SYSTEM”-key the order of encoding values (1 – 14)
can be leafed through.
A “bip” will sound when a key is pressed during normal operation (not during
encode) and the chosen function will be lit.
If one of the encoded alarm limits is exceeded 3 quick “bip2 will be given
(repeated at intervals) and a displayed error code states alarm type.

ENCODING

All encode value are arranged under the “SYSTEM”-key:
The order of encoding values is:

01 =

Working width in cm.

02 =

Wheel circumference in cm.

03 = Flow

figure.

04 = Boom

sections.

05 =

Choice of speed sensor.

06 =

Warning limit application rate.

07 =

Warning limit pressure.

08 =

Warning limit rpm

09 =

+/- change of application rate

10 =

Time factor (automatic dosage).

11 = Uniform

pressure

12 = Metric/Imperial
13 =

Choice of implement sensor

14 = Printer

By means of the “SYSTEM”-key it can be leafed through the order of the above
values, step by step.
The encoding is ended by pressing the “SYSTEM”-key for 3 seconds, whereever
in the order you are.

LH 3000 automatically deletes the “old” encoding value when the encoding is
started.