Pressure sensor motor control implement sensor, Errors and warnings – TeeJet LH 3000 User Manual
Page 23
LH 3000
OPERATING MANUAL
LH
AGRO
23
PRESSURE SENSOR
Press
"t" appears to the left in the display and "ON/OFF" changes to the right when the
pressure sensor is activated.
MOTOR CONTROL
By pressing
or
the regulation valve should go up or down
respectivly.
"+" = up
"-" = down
IMPLEMENT SENSOR
The control lamp on the monitor shows if the implement sensor works.
NB!
Choose the right imple ment sensor in ENCODE point 13.
ERRORS AND WARNINGS
Any warning is given by 3 x "bip" (repeatedly) and an error code which will flash in
the display.
Err 0
Electronics for boom compensation not mounted.
Err 1
Motor valve for automatic application uses too much power.
Err 2
Application warning: over application
Err 3
Application warning: under application
Err 4
Pressure warning: upper warning limit
Err 5
Pressure warning: lover warning limit
Err 6
RPM warning: upper rpm limit
Err 7
RPM warning: lower rpm limit
Err 8
Number of encoded sections do no correspond with switches that are on.
Err 9
The sum of boom widths does not correspond with the encoded working
width.
Err 10
Main valve not off.