OPERATING MANUAL
12
LH A
GRO
05 CHOOSE OF SPEED SENSOR
LH 3000 can operate with 3 individual speed sensors:
1.
Sensor mounted on tractor wheel.
2.
Sensor mounted on trailed implement (can only be connected via electronics
for boom compensation).
3. Radar.
Select sensor by encoding the corresponding number.
NB! Check that wheel circumference corresponds to the selected wheel sensor.
06 ALARM LIMITS FOR APPLICATION RATES
Here the maximum accepted deviation can be encoded. Encode the figure in per
cent.
Is the encoded alarm limit exceeded the alarm will be given as follows:
3 “bip” (repeated at intervals) will sound and simultaneously the display will show:
ERR 2 = over-application
ERR 3 = under-application
NB!
No matter automatic application or not the wanted application rate must
be encoded to make the alarm function work. To be encoded by the
function key “DOS”.
IMPORTANT:
Is no alarm wanted 0 must be encoded.
07 ALARM LIMITS FOR PRESSURE
Here the maximum acceptable deviation of operation pressure of the sprayer is
encoded. Encode in per cent.
NB! This function is only active if a pressure sensor has been mounted on the
sprayer and the wanted operation pressure has been encoded. (See “BAR”-key).
The alarm will be given by 3 “bip” (repeated at fixed intervals) and at the same
time the following will be displayed:
ERR 4 = Pressure too high
ERR 5 = Pressure too low
IMPORTANT:
Is no alarm wanted 0 must be encoded.