13

R0

The operator can either use the

+

key to get back in 10% increments

The operator can push the

+

and keys simultaneously to get back to

the target in one step.


A

UTO

P

OWER

D

OWN


The 844-R console is designed to power
itself off after 10 minutes of no inputs.
This feature keeps the console from
draining the battery on the sprayer if the
operator inadvertently leaves the
console powered on for an extended
period. This only occurs when the
Master boom switch is turned OFF and
the console is not receiving inputs from
any of the sensors (the sprayer is
inactive).

To manually power the console off, refer to the Powering Console On/Off section
of this manual.

Note: When the console display power is “off”, the “Delivery” and
“Agitation” switches can still be operated.

Note: When in the user setup mode, the automatic power down feature is
disabled. However, after 10 minutes without keyboard activity, the console
automatically saves all program changes and exits the program mode. At
this time, the automatic power down feature begins counting and will shut
the console off after 10 minutes.

The programming of the 844-R is divided into two programming categories;
System Setup Mode and User Setup Mode.

The System Setup Mode contains the programming steps that customize
the controller to the applicator or it’s components. These include
calibration steps and parameters that, once programmed, rarely change.

The Application Preset Setup Mode contains target application rate and
orifice or micro tube capacity settings, which are more frequently changed.