KEYING IN PARAMETERS
To make numeric entries into a cursor location that is displayed on a screen
menu, use the numeric keypad. When the desired entry is displayed on the
LCD screen, use the ENTER key to register the new value. Entries are made
left to right.
The CLEAR key will clear an existing value to 0, displayed as a series of
dashes, and relocate the cursor to the extreme left-hand entry position ready
to accept entries again. As soon as a desired value is keyed in and displayed,
pressing the ENTER key makes the system accept that entry. If a number
value is not “Entered,” then it will not be accepted by the system and the
parameter value will return to its former setting (before any numerical values
were changed).
OPERATIONAL FEATURES
– Adjustable Afterburst Timer to separate parts from horn.
– Adjustable tolerance limits in energy (Ws) (XPE models only) and time (sec)
with visual alarms.
– Information displays including: number of assemblies, number of rejects,
and number of cycles.
– Fault displays.
– Keypad security.
– Self-diagnostic input test.
STARTING UP THE PRESS
Press the ON/OFF key to turn the press on. The LCD screen will display
“Sequence” and show wattage and frequency information. Then the LCD
screen will show the following “ready” display:
This display shows the last weld information – weld time, energy (XPE
models only) and power. (After power down and subsequent power up,
values are cleared to zero.)
00.00 sec
000000 J
00 %Pmax