Installation, Electrical power requirements, Air supply – Sonics X-Press Integrated Welder User Manual
Page 10: Setting up, Electrical power requirements air supply

I N S T A L L A T I O N
ELECTRICAL POWER REQUIREMENTS
The press requires a fused, single-phase, standard 3-terminal grounding
type receptacle capable of supplying the requisite voltage and current. Refer
to the table below for power specification.
AIR SUPPLY
The press requires a source of dry, filtered (5 micron), oil-free, compressed
air capable of supplying a constant line pressure of 85 psig. (586 kPa / 6 bar)
at a minimum capacity of 2 CFM.
SETTING UP
The press should be installed in a clear, uncluttered location that is free from
excessive dirt, dust, corrosive fumes, and temperature and humidity ex-
tremes. The selected installation site should be near the electrical power and
air supply sources and away from any equipment that generates abnormally
high electrical transients. Observe the following additional instructions when
installing the press:
a. The press should be placed on a sturdy, level table or bench capable of
supporting a minimum of 500 pounds (227 kg).
b. Do not place anything on top of the press. The ventilation grille should not
be covered by any items. Periodically check the grille and clean as
necessary.
Model
Power Rating
115 vac
230 vac
XP1200
1200w
20 amps
10 amps
XP2200
2200w
N/A
20 amps
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
I N S T R U C T I O N M A N U A L • M O D E L X - P R E S S
9
Do not connect the press
to an air source supplied
by a compressor lubricated
with synthetic oils or oils
containing phosphate
esters or chlorinated hydro-
carbons. This type of
lubricant may cause the air
filter to malfunction, and
the plastic bowl to rupture.
The line cord is equipped
with a 3-prong, grounding
plug. Do not, under any
circumstances, remove the
ground prong. The plug
must be plugged into a
mating 3-prong, grounding
type outlet.
POWER SPECIFICATIONS
Go To Top Of Document