Connections – Sonics X-Press Integrated Welder User Manual
Page 11

KEY COMPONENTS
CONNECTIONS
When making initial air supply or impulse cable connections, make sure all
electrical power is disconnected. Located on the connection plate at the
base of the press head are the following:
1. Connect the air supply source to the press air hose.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
I N S T R U C T I O N M A N U A L • M O D E L X - P R E S S
10
NOTE: Do not strain or kink
cables. When going around
corners, allow as wide a
bend as possible. Do not
run cables parallel to any
power line within a
distance of less than 1 foot
(304.8mm).
CONVERTER HOUSING
with converter, booster &
horn (stack) assembly
PALM BUTTONS
CONVERTER
HOUSING DOOR
EMERGENCY STOP
BUTTON
PRESSURE GAUGE
REGULATOR
HEAD DOWN SWITCH
SPEED CONTROL KNOBS
CONNECTION
PLATE
AIR CONNECTION
Power input,
hardwired cable.
Base/impulse cable.
Line Fuse (based on
requirements listed in “Power
Specifications" table, page 9).
Line Fuse (based on
requirements listed in “Power
Specifications" table, page 9).
Fuse (0.5 amp - internal low
voltage).
MICROPROCESSOR
CONTROLS
Go To Top Of Document