Page 80

background image

Slant Fin Corp.

│ Installation and Operation Instructions

CHS Series

80

Table 15-4 Alert Codes

Code

Description

260

RESERVED

261

DHW set point was invalid

262

DHW time of day set point was invalid

263

DHW storage setpoint was invalid

264

STAT may not be a DHW demand source when Remote Stat is enabled

265

No DHW anticondensation setpoint was configured

266

No CH anticondensation setpoint was configured

267

STAT may not be a CH demand source when Remote Stat is enabled

268

CH 4mA water temperature setting was invalid

269

CH 20mA water temperature setting was invalid

270

Steam 4mA water temperature setting was invalid

271

Steam 20mA water temperature setting was invalid

272

Abnormal Recycle: Pressure sensor fault

273

Abnormal Recycle: Safety relay drive test failed

274

Abnormal Recycle: Demand off during Pilot Flame Establishing Period

275

Abnormal Recycle: LCI off during Drive to Purge Rate

276

Abnormal Recycle: LCI off during Measured Purge Time

277

Abnormal Recycle: LCI off during Drive to Light off Rate

278

Abnormal Recycle: LCI off during Pre-Ignition test

279

Abnormal Recycle: LCI off during Pre-Ignition time

280

Abnormal Recycle: LCI off during Main Flame Establishing Period

281

Abnormal Recycle: LCI off during Ignition period

282

Abnormal Recycle: Demand off during Drive to Purge Rate

283

Abnormal Recycle: Demand off during Measured Purge Time

284

Abnormal Recycle: Demand off during Drive to Light off Rate

285

Abnormal Recycle: Demand off during Pre-Ignition test

286

Abnormal Recycle: Demand off during Pre-Ignition time

287

Abnormal Recycle: Flame was on during Safe Start check

288

Abnormal Recycle: Flame was on during Drive to Purge Rate

289

Abnormal Recycle: Flame was on during Measured Purge Time

290

Abnormal Recycle: Flame was on during Drive to Light off Rate

291

Abnormal Recycle: Flame was not on at end of Ignition period

292

Abnormal Recycle: Flame was lost during Main Flame Establishing Period

293

Abnormal Recycle: Flame was lost early in Run

294

Abnormal Recycle: Flame was lost during Run

295

Abnormal Recycle: Leakage test failed

296

Abnormal Recycle: Interrupted air flow switch was off during Drive to Purge Rate

297

Abnormal Recycle: Interrupted air flow switch was off during Measured Purge Time

298

Abnormal Recycle: Interrupted air flow switch was off during Drive to Light off Rate

299

Abnormal Recycle: Interrupted air flow switch was off during Pre-Ignition test

300

Abnormal Recycle: Interrupted air flow switch was off during Pre-Ignition time

301

Abnormal Recycle: Interrupted air flow switch was off during Main Flame Establishing Period

302

Abnormal Recycle: Ignition failed due to interrupted air flow switch was off

303

Abnormal Recycle: ILK off during Drive to Purge Rate

304

Abnormal Recycle: ILK off during Measured Purge Time

305

Abnormal Recycle: ILK off during Drive to Light off Rate

306

Abnormal Recycle: ILK off during Pre-Ignition test

307

Abnormal Recycle: ILK off during Pre-Ignition time

308

Abnormal Recycle: ILK off during Main Flame Establishing Period