Holding coils for iec starters 30, Replacement blower motors and starters (cont'd), Replacement parts for nema starters – Reznor HRPD Parts Manuals User Manual
Page 30: See replacement information, top of page 27

Form P-RG/RP/RBL, P/N 263984R4, Page 30
Voltage
GE # Reznor
P/N
For Use with Starters
Beginning with GE#
24
LB1A-C
151280 CL00; CL01; CL02; CL25
120
LB1A-J
151281 CL00; CL01; CL02; CL25
208
LB1A-L
151282 CL00; CL01; CL02; CL25
230
LB1A-S
151283 CL00; CL01; CL02; CL25
460
LB1A-U
151284 CL00; CL01; CL02; CL25
575
LB1A-Y
151285 CL00; CL01; CL02; CL25
24
LB3A-C
151286 CL04; CL45
120
LB3A-J
151287 CL04; CL45
208
LB3A-L
151288 CL04; CL45
230
LB3A-S
151289 CL04; CL45
460
LB3A-U
151290 CL04; CL45
575
LB3A-Y
151291 CL04; CL45
208
LB4A-L
151292 CL06; CL07; CL08; CL09
230
LB4A-S
151293 CL06; CL07; CL08; CL09
460
LB4A-U
151294 CL06; CL07; CL08; CL09
Motor Data
Maximum Mtr
Amp Draw
Motor P/N (Volts -
Phase)
IEC Starter
Rated
HP
Century
P/N
Frame 1800
RPM
1200
RPM
208-3
240-3 480-3
Manufacturer's P/N
Reznor
P/N
1/.44
M124 M145T
3.8
2.4
105641
AEG2SP-S17-C-I-H-O
114971
1/.44
M124 M145T
3.4
2.2
105641
AEG2SP-S17-C-I-H-O
114971
1/.44
M109 M145T
1.7
1.1
105642 AEG2SP-S17-E-G-F-O 114972
1.5/.68
M125
N145T
5.4
3.1
105643
AEG2SP-S17-C-K-I-O
114973
1.5/.68
M125
N145T
4.9
2.8
105643
AEG2SP-S17-C-K-I-O
114973
1.5/.68
M104
N145T
2.4
1.4
105644 AEG2SP-S17-E-H-G-O 114974
2/.88
M220
S182T
6.5
4.2
105645
AEG2SP-S17-C-L-K-O
114975
2/.88
M220
S182T
5.9
3.8
105645
AEG2SP-S17-C-L-I-O
114976
2/.88
M207
S182T
3.4
2.1
105646 AEG2SP-S17-E-I-H-O 114977
3/1.3
M221
S184T
9.3
5.3
105647
AEG2SP-S17-C-M-K-O
114978
3/1.3
M221
S184T
8.4
4.8
105647
AEG2SP-S17-C-M-K-O
114978
3/1.3
M208
S184T
4.6
2.6
105648 AEG2SP-S17-E-K-H-O 114979
5/2.2
M320
S215T 17.2
11.3
105870
AEG2SP-S17-C-O-M-O
114980
5/2.2
M320
S215T 15.5
10.2
105870
AEG2SP-S17-C-O-M-O
114980
5/2.2
M305
S215T
7.1
4.8
105871 AEG2SP-S17-E-L-K-O 114981
7.5/3.3
M317
Y215T 21.6
13.6
105872
AEG2SP-S17-C-O-N-O
114982
7.5/3.3
M317
Y215T 19.5
12.3
105872
AEG2SP-S17-C-O-N-O
114982
7.5/3.3
M315
D215T 10.0
6.0
105873 AEG2SP-S17-E-M-L-O 114983
10/4.4
M421
S256T 31.0
19.4
105874
AEG2SP-S17-C-P-O-O
114984
10/4.4
M421
S256T 28.0
17.5
105874
AEG2SP-S17-C-P-O-O
114984
10/4.4
M413
S256T 13.5
7.5
105875 AEG2SP-S17-E-N-L-O 114985
Replacement Holding
Coils for IEC Starters
2-Speed Blower Motors
IEC Two-Speed Starter
Effective 9/91, IEC two-speed starters are
used. Prior to 9/91, units with 2-speed motors
were equipped with NEMA starters. If replacing
a NEMA starter with an IEC starter, replace the
complete starter. See terminal cross reference
chart (right).
Original box and cover may be used for
replacement IEC starter.
Replacement Parts for
NEMA Starters
Terminal Cross-Reference Chart
for Replacement IEC Starters
NEMA
IEC
Starter Wire Terminals
High
Speed
D
2T1
F
6T3
E
4T2
Low
Speed
A
2T1
C
6T3
B
4T2
Relay/Starter Coil Terminals
9
96 95
Premium Efficient Motor
Frame
Size
Service
Factor
Power
Factor
Starter (AN10)
Starter Overload
Type HP AL
Mfr's #.
P/N
fla
volt ph
Mfr #
P/N
Mfr #
min
max
P/N
EE
15 43
EFM2513T-8
142440 40.7 208
3
254T
1.15
84
CL06A311M-L
151173
RTA2-E 30.00 43.00
151206
EE
EFM2513T
142441 35.4 240
3
254T
1.15
84
CL06A311M-S
151172
RTA2-E 30.00 43.00
151206
EE
EFM2513T
142441 17.7 480
3
254T
1.15
84
CL25A310T-U
151162
RTA1-T 17.50 22.00
151197
EE
EFM2513T-5
142289 16.0 575
3
254T
1.15
84
CL02A310T-Y
151158
RTA1-P 10.00 16.00
151194
EE
20 44
E452-F2
159187 57.0 208
3 S256T
1.15
84
CL07A311M-L
151176
RTA2-H 54.00 65.00
151203
EE
EFM2515T
142299 47.0 240
3
256T
1.15
84
CL06A311M-S
151172
RTA2-G 42.00 55.00
151202
EE
EFM2515T
142299 23.5 480
3
256T
1.15
84
CL04A310M-U
151167
RTA1-U 21.00 26.00
151198
EE
EFM2515T-5
142300 19.2 575
3
256T
1.15
84
CL25A310T-Y
151163
RTA1-T 17.50 22.00
151197
Replacement Blower Motors and Starters (cont'd) -