background image

Form P-RG/RP/RBL, P/N 263984R4, Page 14

5” Vent Cap,

P/N 110052

5” dia. Vent Pipe

Support angles

for flue pipe.

Recommended

type is 1/2”x1/2”,

20 gauge.

4 ft

(1.2M)

5” dia.

90° Elbow

18” (457mm)

straight pipe

Oval Adapter Assy,

P/N 103025, and

Seal Plate,

P/N 43446

Combustion

Air Intake

Code 168 - Vertical Vent Kit,

P/N 45021 (Same as Option CC3)

Model RP Cabinet and Collection Box Parts - Same parts apply to RP duct furnaces in

packaged Model Series HRPD, RPB, RPBL, & RPDBL

(Quantities listed are per furnace section.)

®

Label, P/N 196689

Gray Sealant (3M 900 Duct Sealer Fast

Bond), P/N 100117

155

160

161

159

153

152

151

165

156

154

159B,C,D

157/158

163

157B/C

NOTES: Support angles and all piping are field

supplied. One kit for each furance section.

Flue Collection Box and Venter for single furnace RP/RPB Series

units without Opt AG 39 or 40, and multiple furnace units (Model

HRPD and RPBL) without Option AG 41 or 42 and 2nd and 3rd

furnaces on units with Option 41 or 42.

Options AG 39, 40, 41 or 42 (1st furnace only w/Opt AG 41 & 42)

130

133

139

135

(Size 125)

Flue Duct

(see detail

view right)

135

(Sizes 150-400)

Flue Duct

Assembly with

Gear Motor and

Flue Collection

Box

NOTE: AG 39 and 40 apply to RP series models with one furnace. AG 41 and

42 apply to models with more than one furnace (HRPD, RPBL). Flue duct and

gear motor parts shown here apply to the first furnace section only.

Basic Exterior Parts for Model RP

Furnace

Cabinet Connector & Filler Parts for Multiple Furnaces - Models HRPD & RPBL

HRPD Size

250 300/350 400 500/600 700

800

-

-

RPBL Size

-

-

400 500/600 700

800

1050

1200

Top Filler

111092 111093 111094 105629 105630 105631

(2)

105630

(2)

105631

Gasket

(2)

103605

(2)

103606

(2)

103607

(2)

103608

(2)

103609

(2)

103610

(4)

103609

(4)

103610

Side Filler

(2) 105632

(4)

105632

Top & Btm Duct

Connector

(2)

107427

(2)

107428

(2)

107429

(2)

106338

Side Duct

Connector

(2)

106395

(4)

106395

133

130

131

132

144

145 Restrictor (Sizes 125-250)

145 Inlet Ring (Sizes 300 and 400)

148

146

147

150A

150B

147A/B

138

137

136

139

Terminal Block

150A 150B

134

144

145

146

147

147A/B

148

125-300 Inlet Ring

400 - Mounting Plate

149

143 - Gasket

(142 - Cover -

not illustrated)

Inlet Ring to Wheel

measurement - Sizes 125-350

.

056

Mounting Plate to Wheel

measurement - Size 400

.306

Assembly with Gear Motor and Venter

This manual is related to the following products: