Fan motor capacitor 5, 6, Circuit board 5, 6, Circuit board (dsi ignition cntrl) 5 – Reznor UDBP Parts Manuals User Manual
Page 5: Disconnect switch 5, Flame sensor 5, 6, Fuse 5, Limit control 5, 6, Fan motor 5, 6, Pressure switch 5, 6, Disconnect switch 5, 6

Form P-UD, P/N 270285R4, Page 5
Flame Sensor
Pressure
Switch*
Limit
Control
Venter
Motor
page 13
Direct Drive
Blower and
Motor Assy, page 8
Burner
A
ssembly
, page 14
Ignitor
Orifice
Gas
Valve
Door Interlock
(UDBS only)
Terminal Board
and Gasket
Disconnect Switch
(UDBS only)
Electrical Box (UDBS only)
Top View of Control
Bracket Assy located on the
Control Compartment Bottom
Control
Transformer
Ignition
Board
Capacitor, page 8 (located
on the opposite side of
the blower housing)
10A
14
8
9
18
20
16,17
19
7
15
5,6
Control Bracket
and Gasket only
Box
Cover
1, 2, 3
*Prior to 9/03, pressure switch was located on the inner wall just above the limit control.
Pressure
switch
location
prior to 9/03.
Control Compartment -
Models UDBP
Sizes 30-125
Code Description
Model
30
45
60
75
100
125
150
175
200
225
250
300
350
400
1A High Temperature Limit Control,
Auto Reset (
NOTE: Color listed
is the color of the identifying dot
on the limit control label. “None”
indicates no colored dot on the
label.)
UDAP/UDAS
96512, 220°F, Blue
45602, 180°F, None
85449,
200°F,
Yellow
45602,
180°F,
None
82091,
160°F,
Red
45602,
180°F,
None
82091,
160°F,
Red
45602,
180°F,
None
85449,
200°F,
Yellow
45602, 180°F, None
UDBP/UDBS
201961, 275°F,
Green
96512,
220°F,
Blue
85449, 200°F, Yellow
96512,
220°F,
Blue
201961,
275°F,
Green
45602,
180°F,
None
202048, 240°F,
Silver
45602, 180°F,
None
201962,
250°F,
Orange
202048,
240°F,
Silver
85449,
200°F,
Yellow
1B High Temperature Limit Control,
Auto Reset - UDAP w/Opt AL2B
UDAP-45LN
(low noise)
N/A
85449,
200°F,
Yellow
N/A
2
Limit Control Plate
All
170025
3
Limit Control Bracket
UDAP/UDAS
170026
UDBP/UDBS
201771
202701
4
Flame Rollout Switch, Manual
Reset
UDAP/UDAS
197033, 210°F /
-31°F, Violet Dot 196949, 225°F / -31°F, Red Dot
196950, 250°F /
-31°F, Yellow Dot
--
--
--
--
--
--
--
--
5
Control Mounting Bracket
UDAP/UDAS
195551
195294
UDBP
195551
202736
UDBS
195551
195294
6
Cntrl Mounting Bracket Gasket
All
195664
195669
7
Circuit Board (DSI Ignition Cntrl)
All
195265, UTC 1097-210, Serial No.Code 79
7A Fuse for Circuit Board
All
P/N
201685 or replace with a field-supplied Type ATC or ATO 3 amp fuse, Color Code Violet.
8
Flame Sensor
All
195292
9
Ignitor (Electrode Assy)
All
175272
10A Transformer
115V
UDAP/UDAS
175265, 25VA
All*
194808, 40 VA (*40VA transformer only applies to UDAP and UDAS when equipped with multiple heater control Option CL31)
208V-230V/1ph
194536, 40 VA
208V-230V/3ph
UDBP/UDBS
--
--
--
--
--
--
194536, 40 VA
10B
**
Xformer w/
Opts D10/14
DDC Cntrls
115V
UDAP/UDAS
150-400 with
Opt D10&D14
N/A
175265, 25VA and 194808, 40VA
208V-230V/1ph
N/A
(2)
194536, 40 VA
11
Stepdown
Transformer
480V supply-120V
UDBP/UDBS
--
--
--
--
--
--
11100 , 1/2 KVA
575V supply-120V
--
--
--
--
--
--
202056, 575/120
12A Fan Motor
(See spac-
ing, pg 6.)
115V Open
UDAP/UDAS
196240
196241
196242
196243
196244
196245
196246
196247
115V TEFC (AL14)
203310
203724
196824
196825 (Must be Fasco Rev D)
***
208/230V Open
196826 ***
195302 ***
195303 ***
12B Fan Mtr 115V w/Opt AL2B
UDAP45-LN
N/A
203030
N/A
13
Fan Motor Capacitor
115V
--
--
--
195642 (on units manufactured
beginning 2/2011)
195643, 7.5 mfd
208/230V
--
--
--
--
195643, 7.5 mfd
115Vw/AL14
--
--
--
--
195642, 5 mfd
195643, 7.5 mfd
217031, 15mfd
14
Pressure Switch, 0 to 6000
ft (Above 6000 ft, see kits on
page 16.)
NOTE: Color listed is the
identifying color of the pressure
switch label.
UDAP-CV ****
197028, .65”
w.c., Yellow
196388,
.50” w.c.,
Orange
197029, .60” w.c.,
Light Blue
196362,
.55” w.c.,
White
--
--
--
--
--
--
--
--
--
UDAP
197030, 40” w.c., Green
196388, .50” w.c., Orange
197030, 40” w.c., Green
201158, 1.10” w.c., Blue
201158, 1.10” w.c.,
blue, on Sizes 350 &
400 mfgd beginning
7/23/2009.
201159, 1.40” w.c., red,
Sizes 350 & 400 mfgd
prior to 7/23/2009
UDAS
197028, .65” w.c., Yellow
196362,
.55” w.c.,
White
197032,
.45” w.c.,
Pink
197030,
.40” w.c., Green
201158, 1.10” w.c., Blue
UDBP
197030,.40” w.c., Green
196388, .50” w.c.,
Orange
197030,.40” w.c.,
Green
197030,
.40” w.c., Green
201158, 1.10” w.c., Blue
UDBS
197030,
.40” w.c.,
Green
196388,
.50” w.c.,
Orange
197029,
.60” w.c.,
Lt Blue
196388,
.50” w.c.,
Orange
197030,
.40” w.c.,
Green
197032,
.45” w.c.,
Pink
197030,
.40” w.c.,
Green
201158, 1.10” w.c., Blue
15
Gas Valve
Natural, 1-Stage
All
(Serial No.
Valve Code in
parenthesis -
see page 3.)
260603, 1/2x1/2, MH VR8215T1239, (6E)
196981, 3/4x3/4, MH VR8305K4241, (Y3 or Z8)
Propane, 1-Stage
263999, 1/2x1/2, MH VR8215T5214, (9E)
196983, 3/4x3/4, MH VR8305K4258, (Y5 or 1A)
Natural, 2-Stage
--
--
197066, 1/2x1/2, MH VR8205N2921, (Y8 or 4A)
197067, 3/4x3/4, MH VR8305N4297, (Y9 or 5A)
Propane, 2-Stage
--
--
197064, 1/2x1/2, MH VR8205N2913, (Y6 or 2A)
197065, 3/4x3/4, MH VR8305N4289, (Y7 or 3A)
16
Terminal Board (24V), 4 pole
All
196813
17
Terminal Board Gasket
UDAS and
UDBS only
196327
18
Electrical Box Cover
201945
19
Door Switch
217262, Carling #TA22B-TLB-B
20
Disconnect Switch
101902 (after 10/06) / (201946 before 10/06)
101902 (replaced 202054)
21
Wiring Harness with 9 pin
Terminal
UDAP/UDAS
197148
197199
197149
201417
201418
201419
UDBP/UDBS
203523
203524
203525
203526
203527
203528
22
Wiring Harness w/ 5 pin Terminal
All
195653
195656
**
For location, see page 7.
***
When inventory of the 208/230V fan motors is depleted, they will no longer be available as replacement parts. A replacement 115V motor and the installation of a
stepdown transformer kit (Opt CG1 or 2, page 7) will be required. Check with your distributor for availability.
****
Model UDAP-CV is a Model UDAP with factory-installed Common Vent Option AV6