beautypg.com

Fan motor capacitor 5, 6, Circuit board 5, 6, Circuit board (dsi ignition cntrl) 5 – Reznor UDBP Parts Manuals User Manual

Page 5: Disconnect switch 5, Flame sensor 5, 6, Fuse 5, Limit control 5, 6, Fan motor 5, 6, Pressure switch 5, 6, Disconnect switch 5, 6

background image

Form P-UD, P/N 270285R4, Page 5

Flame Sensor

Pressure

Switch*

Limit

Control

Venter

Motor

page 13

Direct Drive

Blower and

Motor Assy, page 8

Burner

A

ssembly

, page 14

Ignitor

Orifice

Gas

Valve

Door Interlock

(UDBS only)

Terminal Board

and Gasket

Disconnect Switch

(UDBS only)

Electrical Box (UDBS only)

Top View of Control

Bracket Assy located on the

Control Compartment Bottom

Control

Transformer

Ignition

Board

Capacitor, page 8 (located

on the opposite side of

the blower housing)

10A

14

8

9

18

20

16,17

19

7

15

5,6

Control Bracket

and Gasket only

Box

Cover

1, 2, 3

*Prior to 9/03, pressure switch was located on the inner wall just above the limit control.

Pressure

switch

location

prior to 9/03.

Control Compartment -

Models UDBP

Sizes 30-125

Code Description

Model

30

45

60

75

100

125

150

175

200

225

250

300

350

400

1A High Temperature Limit Control,

Auto Reset (

NOTE: Color listed

is the color of the identifying dot

on the limit control label. “None”

indicates no colored dot on the

label.)

UDAP/UDAS

96512, 220°F, Blue

45602, 180°F, None

85449,

200°F,

Yellow

45602,

180°F,

None

82091,

160°F,

Red

45602,

180°F,

None

82091,

160°F,

Red

45602,

180°F,

None

85449,

200°F,

Yellow

45602, 180°F, None

UDBP/UDBS

201961, 275°F,

Green

96512,

220°F,

Blue

85449, 200°F, Yellow

96512,

220°F,

Blue

201961,

275°F,

Green

45602,

180°F,

None

202048, 240°F,

Silver

45602, 180°F,

None

201962,

250°F,

Orange

202048,

240°F,

Silver

85449,

200°F,

Yellow

1B High Temperature Limit Control,

Auto Reset - UDAP w/Opt AL2B

UDAP-45LN

(low noise)

N/A

85449,

200°F,

Yellow

N/A

2

Limit Control Plate

All

170025

3

Limit Control Bracket

UDAP/UDAS

170026

UDBP/UDBS

201771

202701

4

Flame Rollout Switch, Manual

Reset

UDAP/UDAS

197033, 210°F /

-31°F, Violet Dot 196949, 225°F / -31°F, Red Dot

196950, 250°F /

-31°F, Yellow Dot

--

--

--

--

--

--

--

--

5

Control Mounting Bracket

UDAP/UDAS

195551

195294

UDBP

195551

202736

UDBS

195551

195294

6

Cntrl Mounting Bracket Gasket

All

195664

195669

7

Circuit Board (DSI Ignition Cntrl)

All

195265, UTC 1097-210, Serial No.Code 79

7A Fuse for Circuit Board

All

P/N

201685 or replace with a field-supplied Type ATC or ATO 3 amp fuse, Color Code Violet.

8

Flame Sensor

All

195292

9

Ignitor (Electrode Assy)

All

175272

10A Transformer

115V

UDAP/UDAS

175265, 25VA

All*

194808, 40 VA (*40VA transformer only applies to UDAP and UDAS when equipped with multiple heater control Option CL31)

208V-230V/1ph

194536, 40 VA

208V-230V/3ph

UDBP/UDBS

--

--

--

--

--

--

194536, 40 VA

10B

**

Xformer w/

Opts D10/14

DDC Cntrls

115V

UDAP/UDAS

150-400 with

Opt D10&D14

N/A

175265, 25VA and 194808, 40VA

208V-230V/1ph

N/A

(2)

194536, 40 VA

11

Stepdown

Transformer

480V supply-120V

UDBP/UDBS

--

--

--

--

--

--

11100 , 1/2 KVA

575V supply-120V

--

--

--

--

--

--

202056, 575/120

12A Fan Motor

(See spac-

ing, pg 6.)

115V Open

UDAP/UDAS

196240

196241

196242

196243

196244

196245

196246

196247

115V TEFC (AL14)

203310

203724

196824

196825 (Must be Fasco Rev D)

***

208/230V Open

196826 ***

195302 ***

195303 ***

12B Fan Mtr 115V w/Opt AL2B

UDAP45-LN

N/A

203030

N/A

13

Fan Motor Capacitor

115V

--

--

--

195642 (on units manufactured

beginning 2/2011)

195643, 7.5 mfd

208/230V

--

--

--

--

195643, 7.5 mfd

115Vw/AL14

--

--

--

--

195642, 5 mfd

195643, 7.5 mfd

217031, 15mfd

14

Pressure Switch, 0 to 6000

ft (Above 6000 ft, see kits on

page 16.)

NOTE: Color listed is the

identifying color of the pressure

switch label.

UDAP-CV ****

197028, .65”

w.c., Yellow

196388,

.50” w.c.,

Orange

197029, .60” w.c.,

Light Blue

196362,

.55” w.c.,

White

--

--

--

--

--

--

--

--

--

UDAP

197030, 40” w.c., Green

196388, .50” w.c., Orange

197030, 40” w.c., Green

201158, 1.10” w.c., Blue

201158, 1.10” w.c.,

blue, on Sizes 350 &

400 mfgd beginning

7/23/2009.

201159, 1.40” w.c., red,

Sizes 350 & 400 mfgd

prior to 7/23/2009

UDAS

197028, .65” w.c., Yellow

196362,

.55” w.c.,

White

197032,

.45” w.c.,

Pink

197030,

.40” w.c., Green

201158, 1.10” w.c., Blue

UDBP

197030,.40” w.c., Green

196388, .50” w.c.,

Orange

197030,.40” w.c.,

Green

197030,

.40” w.c., Green

201158, 1.10” w.c., Blue

UDBS

197030,

.40” w.c.,

Green

196388,

.50” w.c.,

Orange

197029,

.60” w.c.,

Lt Blue

196388,

.50” w.c.,

Orange

197030,

.40” w.c.,

Green

197032,

.45” w.c.,

Pink

197030,

.40” w.c.,

Green

201158, 1.10” w.c., Blue

15

Gas Valve

Natural, 1-Stage

All

(Serial No.

Valve Code in

parenthesis -

see page 3.)

260603, 1/2x1/2, MH VR8215T1239, (6E)

196981, 3/4x3/4, MH VR8305K4241, (Y3 or Z8)

Propane, 1-Stage

263999, 1/2x1/2, MH VR8215T5214, (9E)

196983, 3/4x3/4, MH VR8305K4258, (Y5 or 1A)

Natural, 2-Stage

--

--

197066, 1/2x1/2, MH VR8205N2921, (Y8 or 4A)

197067, 3/4x3/4, MH VR8305N4297, (Y9 or 5A)

Propane, 2-Stage

--

--

197064, 1/2x1/2, MH VR8205N2913, (Y6 or 2A)

197065, 3/4x3/4, MH VR8305N4289, (Y7 or 3A)

16

Terminal Board (24V), 4 pole

All

196813

17

Terminal Board Gasket

UDAS and

UDBS only

196327

18

Electrical Box Cover

201945

19

Door Switch

217262, Carling #TA22B-TLB-B

20

Disconnect Switch

101902 (after 10/06) / (201946 before 10/06)

101902 (replaced 202054)

21

Wiring Harness with 9 pin

Terminal

UDAP/UDAS

197148

197199

197149

201417

201418

201419

UDBP/UDBS

203523

203524

203525

203526

203527

203528

22

Wiring Harness w/ 5 pin Terminal

All

195653

195656

**

For location, see page 7.

***

When inventory of the 208/230V fan motors is depleted, they will no longer be available as replacement parts. A replacement 115V motor and the installation of a

stepdown transformer kit (Opt CG1 or 2, page 7) will be required. Check with your distributor for availability.

****

Model UDAP-CV is a Model UDAP with factory-installed Common Vent Option AV6

This manual is related to the following products: