Wiring dia gram – Reznor R6GF Unit Installation Manual User Manual
Page 30

30
CCH
IF
EQUIPPED
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
240V
208V
24V
COM
1
2
3
1
2
3
L
W2
Y2
R
C
Y1
G
W1
5432
1
5432
1
VA
RIABLE
SPEED
BLO
WER
MO
TO
R
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
R
S
C
R
S
C
C
HF
TO
208/230
VA
C
PO
WER SUPP
LY
FLAME
SENSOR
HPS
INDUCER
MO
TO
R
IGNIT
OR
LO
W
PRESSURE
SWITCH
HIGH
PRESSURE
SWITCH
L2
L1
T1
T2
P6 16-PIN
2
1
3
6
5
4
7
8
9
12
11
10
W1
W2
C
R
G
Y
Y2
0
DEHUM
NEUTRALS
HUM
LINE
XMFR
CO
NT
EA
C
CO
OL
PA
RK1
PARK2
HI-HEA
T
LO
-HEA
T
P2
1
5
LPS
TRANSFORMER
HIGH
TEMP
LIMIT
OUTDOOR
F
AN MO
TO
R
DU
AL
CAP
A
CIT
OR
ECONOMIZER
PLUG
ECONOMIZER
PLUG
ECONOMIZER JUMPER
HARNESS ASSY
. 8-WIRE
COMFOR
T
ALER
T
Y2
Y
C
R
S
L
R
C
DC
SOL
YELLO
W
BLACK
BLUE
YELLOW
ORANGE
BR
OW
N
BR
OW
N
(CFM)
YEL
GREEN
HI/LO
DEHUMIDIFY
IGNITION / BLO
WER
CONTR
OL BO
ARD
(HIGH HE
AT
DEMAND)
GREEN
(S
TA
TUS)
RED
AU
TO
HEA
T ST
AG
E
10 5 NONE
COOL
A B C D
HEA
T
A B C D
ADJUST
NORM
(+)
(-)
TEST
5A FUSE
HI
LO
PRIMAR
Y
GAS
VA
LV
E
C
2
1
3
AIR SENSOR
TO
DISCHARGE
FLAME R
OLL-OUT
BLA
CK
WHITE
RED
RED
RED
RED
R
O
S
S
E
R
P
M
O
C
RED
YELLO
W
YELLO
W
RED
ORANGE
BLUE
YELLOW
BLACK
GRA Y
GREEN
YELLOW
CONTR
OL
WIRING LEADS
Ref
er to Installation Instr
uctions f
or
Connection to Indoor
Ther
mostat
Note:
See Installation Instr
uctions
for specific
bl
ow
er speed setting.
WHITE
WHITE
GREEN
YELLO
W
VIOLET
ORANGE
BLUE
BLUE
YELLO
W
BR
OW
N
GREEN
RED
BLACK
RED
YELLOW
BLUE
BR
OW
N
WHITE
RED
RED
BLACK
BLA
CK
BLA
CK
BL
AC
K
YELL
OW
YELL
OW
YELL
OW
BLA
CK
YELLOW
BLUE
BLUE
GREEN
GREEN
BLACK
RED
BROW
N
BR
OW
N
RED
BLA
CK
RED
WHITE
BROW
N
BROW
N
YE/BK
BK/WH
BLA
CK
WHITE
BLA
CK
RED
GRA
Y
BLA
CK
YELLO
W
BLUE
GREEN
208/230
V
olt Single Phase
Pa
ck
ag
ed
Tw
o Stage Heat/T
wo
Stage Electric Air Conditioner
60Hz
WIRING DIA
GRAM
NO
TES:
1.
Disconnect po
wer bef
ore servicing.
2.
For supp
ly
connections use copper conductor
s onl
y.
3.
Not suitable on systems that e
xceed 150V to gr
ound.
1.
Couper le courant
av
ant de faire letretien.
2.
Empl
oy
ez uniquement des conducteu
rs
en cuivre
.
3.
Ne con
vient pas aux installations de plus de 150
V
a la terr
e.
4.
If an
y of the original wire as supplied with the furnace m
ust be replaced,
it m
ust
be replaced with wiring material ha
ving a temperature rating of at least 105°C.
5.
For supp
ly
wire ampacities and o
ver
current pr
otection
,
see unit rating plat
e.
FIELD
WIRING
LEGEND:
LO
W
VO
LT
AG
E
HIGH
VO
LT
AG
E
SYSTEM ST
A
TUS - IGNITION
Po
wer On (Nor
mal Operation)
High Limit Circuit Open
Pressure Switch Open with Inducer On
Pressure Switch Closed with Inducer Off
F
ailed Ignition (5 attemps) - Control in 1 Hour Loc
ko
ut
208-230
V
olt P
olar
ity Issue
Excess High limit tr
ips (5) within one call f
or heat
Excess pressure s
witch cycles (5) within one call f
or heat
Excess flame dropouts (5) within one call f
or heat
Not Used
Flame present with gas
va
lv
e Off
LED ST
A
TUS (RED)
ON
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
7 Flashes
8 Flashes
9 Flashes
10 Flashes
SYSTEM ST
A
TUS - 2nd ST
A
GE HEA
T DEMAND
No demand f
or 2nd stage heat
2nd stage heat demand (Nor
mal operation)
2nd stage heat demand, high pressure
sw
itch not closed
LED ST
A
TUS (GREEN)
OFF
ON
Flashing
SYSTEM ST
A
TUS - CFM
NO
T USED
LED ST
A
TUS (YELLO
W)
OFF
SYSTEM ST
A
TUS - HI/LO DEHUMIDIFY (Cooling Mode on
ly
)
F
actor
y jumper wire
“R
”
to
“DEHUM”
in place or
“Close on F
all”
humidistat (Lo
w humidity) - Closed
Humidistat open (High Humidity) Lo
w Speed Bl
ow
er call
LED ST
A
TUS (GREEN)
ON
OFF
7111830
(Replaces 7111420)
11/11
HI
LO
PRIMAR
Y
GAS
VA
LV
E
C
GAS
VA
LV
E
624787
GAS
VA
LV
E
624652
BR
OW
N
YELLO
W
YELLO
W
BR
OW
N
GRA
Y
Figure 13. Two Stage Cool, Two Stage Heat with Optional Comfort Alert