Wiring dia gram, 29 figure 12. two stage cool, two stage heat – Reznor R6GF Unit Installation Manual User Manual
Page 29

29
Figure 12. Two Stage Cool, Two Stage Heat
CCH
IF
EQUIPPED
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
240V
208V
24V
COM
1
2
3
1
2
3
HI
LO
PRIMAR
Y
GAS
VA
LV
E
C
L
W2
Y2
R
C
Y1
G
W1
54321
54321
VA
RIABLE
SPEED
BLO
WER
MO
TO
R
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
R
S
C
R
S
C
C
HF
TO
208/230
VA
C
PO
WER SUPPL
Y
FLAME R
OLL-OUT
FLAME
SENSOR
HPS
LO
W PRESSURE
SWITCH
HIGH
PRESSURE
SWITCH
L2
L1
T1
T2
2
1
3
6
5
4
7
8
9
12
11
10
W1
W2
C
R
G
Y
Y2
0
DEHUM
P2
1
5
LPS
TRANSFORMER
HIGH
TEMP
LIMIT
OUTDOOR
F
AN MO
TO
R
DU
AL
CAP
A
CIT
OR
AIR SENSOR
TO
DISCHARGE
ECONOMIZER JUMPER
HARNESS ASSY
. 8-WIRE
IGNIT
OR
BR
OW
N
BR
OW
N
INDUCER
MO
TO
R
BLACK
BLUE
BLUE
BLUE
YELLOW
ORANGE
YELLO
W
HUM
LINE
XMFR
CO
NT
EA
C
CO
OL
PA
RK1
PARK2
HI-HEA
T
LO
-HEA
T
NEUTRALS
P6 16-PIN
ECONOMIZER
PLUG
ECONOMIZER
PLUG
(CFM)
YEL
GREEN
HI/LO
DEHUMIDIFY
IGNITION / BLO
WER
CONT
RO
L BO
ARD
(HIGH HE
AT
DEMAND)
GREEN
(S
TA
TUS)
RED
AU
TO
HEA
T ST
AG
E
10 5 NONE
COOL
A B C D
HE
AT
A B C D
ADJUST
NORM
(+)
(-)
TEST
5A FUSE
2
1
3
RED
COMPRESSOR
RED
RED
YELL
OW
YELL
OW
RED
YELLOW
VIOLET
YELL
OW
GRA
Y
BLA
CK
CONTR
OL
WIRING LEADS
Ref
er to Installation Instr
uctions f
or
Connection to Indoor
Ther
mostat
BROW
N
BROW
N
BLA
CK
WHITE
RED
Note
:
See Installation Instr
uctions
for specific
bl
ow
er speed setting.
BLA
CK
GREEN
WHITE
WHITE
RED
RED
WHITE
ORANGE
BLUE
BLUE
GREEN
BLA
CK
BLA
CK
BR
OW
N
BLA
CK
WHITE
RED
YELLOW
BLUE
GREEN
BLACK
RED
BROW
N
RED
BLA
CK
WHITE
GREEN
YELLO
W
BLUE
BR
OW
N
BLA
CK
RED
BL
AC
K
YELLO
W
YELL
OW
RED
RED
ORANGE
BLUE
YELLOW
BLACK
GRA Y
GREEN
BK/WH
YE/BK
BLACK
BLUE
GREEN
YELLO
W
YELLO
W
WIRING DIA
GRAM
208/230
V
olt Single Phase
Pa
ck
ag
ed
Tw
o Stage Heat/T
wo
Stage Electric Air Conditioner
60Hz
WIRING DIA
GRAM
NO
TES:
1.
Disconnect po
wer bef
ore servicing.
2.
For supp
ly
connections use copper conductor
s onl
y.
3.
Not suitable on systems that e
xceed 150V to gr
ound.
1.
Couper le courant
av
ant de faire letretien.
2.
Empl
oy
ez uniquement des conducteur
s en cuivre
.
3.
Ne con
vient pas aux installations de plus de 150
V
a la terr
e.
4.
If an
y of the original wire as supplied with the furnace m
ust be replaced,
it m
ust
be replaced with wiring material ha
ving a temperature rating of at least 105°C.
5.
For supp
ly
wire ampacities and o
ver
current pr
otection
,
see unit rating plate
.
FIELD
WIRING
LEGEND:
LO
W
VO
LT
AG
E
HIGH
VO
LT
AG
E
SYSTEM ST
A
TUS - IGNITION
Po
wer On (Nor
mal Operation)
High Limit Circuit Open
Pressure Switch Open with Inducer On
Pressure Switch Closed with Inducer Off
F
ailed Ignition (5 attemps) - Control in 1 Hour Loc
ko
ut
208-230
V
olt P
olar
ity Issue
Excess High limit tr
ips (5) within one call f
or heat
Excess pressure s
witch cycles (5) within one call f
or heat
Excess flame dropouts (5) within one call f
or heat
Not Used
Flame present with gas
va
lv
e Off
LED ST
A
TUS (RED)
ON
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
7 Flashes
8 Flashes
9 Flashes
10 Flashes
SYSTEM ST
A
TUS - 2nd ST
A
GE HE
AT
DEMAND
No demand f
or 2nd stage heat
2nd stage heat demand (Nor
mal operation)
2nd stage heat demand, high pressure
sw
itch not closed
LED ST
A
TUS (GREEN)
OFF
ON
Flashing
SYSTEM ST
A
TUS - CFM
NO
T USED
LED ST
A
TUS (YELLO
W)
OFF
SYSTEM ST
A
TUS - HI/LO DEHUMIDIFY (Cooling Mode on
ly
)
F
actor
y jumper wire
“R
”
to
“DEHUM”
in place or
“Close on F
all”
humidistat (Lo
w humidity) - Closed
Humidistat open (High Humidity) Lo
w Speed Bl
ow
er call
LED ST
A
TUS (GREEN)
ON
OFF
7111820
(Replaces 7111270)
11/11
HI
LO
PRIMAR
Y
GAS
VA
LV
E
C
GAS
VA
LV
E
624787
GAS
VA
LV
E
624652
BR
OW
N
YELLO
W
YELLO
W
BR
OW
N
GRA
Y