Figure 10. typical Heat Pump thermostat Connections

BLOWER

MOTER

GND

BLACK

BLACK

GREEN

BROWN

TO FIELD
SUPPLIED DISCONNECT

SINGLE STAGE

HEAT PUMP THERMOSTAT

OUTDOOR

SECTION

NOTE 1

NOTE 2

FREEZESTAT

TYPICAL HEAT PUMP THERMOSTAT CONNECTION (NO ECONOMIZER)

AIR HANDLER

SECTION

TERMINAL

BOARD

G

C

W2

O

R

Y

W1

C

Y

R

G Y

E

R O

B

L1

L2

L3

O

W2

W2

C

NOTES:

1. Jumper between

W2 and E is required.

2.

C &W2 to be connected to electric heat.

NOTES:

1. Jumper between

W2 and E is required.

2.

C & W2 to be connected to electric heat.

3. Remove

BLACK wire from air handler low voltage terminal board

Y terminal and connect to YELLOW wire from economizer.

4. 2nd Stage refrigerant cooling with optional economizer installed. A 2
stage thermostat is required for simultaneous operation of the economizer
and refrigerant system. Connect

Y2 from 2 stage thermostat to BLUE

wire from economizer. If installing an economizer in this unit, refer to the
Economizer installation instructions for proper set up and operation.
5. Heat Pump Economizer Relay. Connect

B from thermostat to GREY

wire from Economizer. Required for proper operation of an economizer
(optional) in the heat pump Heating mode. If installing an economizer in
this unit, refer to the Economizer installation instructions for proper set
up and operation.

TYPICAL HEAT PUMP THERMOSTAT CONNECTION (WITH ECONOMIZER)