beautypg.com

Reznor B Option - Power Venter Installation User Manual

Option description, Components, Applies to: model f and b unit heaters

background image

Form I-F/B-PV, P/N 97967R2, Page 1

Installation Instructions for Power

Venter, Options CA1, CA2, and CA3

Form I-F/B-PV (Version A)

Obsoletes Form I-F/B-PV

APPLIES TO: Model F and B Unit Heaters

Option Description

WARNING: This venter and flue adapter are designed FOR USE WITH REZNOR

®

MODEL F or

MODEL B unit heaters ONLY. This venter is not applicable to other Reznor brand products

or to appliances not manufactured as Reznor products.

Components

An Option CA Power Venter is a motorized vent exhauster that is designed to permit

the operation of Reznor

®

gravity-vented Model F and Model B unit heaters in areas

of negative pressure up to 0.15" w.c. or where horizontal venting is required. Before

beginning installation:

Read these entire installation instructions.

Check your option kit to be sure that it is the appropriate option for your heater.

Note that the size of the vent pipe changes with the addition of this venter (See

Paragraph 8).

When installation of the power venter is completed, place this instruction booklet in

the instruction envelope supplied with the heater.

It is important that this booklet be

kept for future reference.

Models F and B Size

25-100

125

130-200

250-400

Option Package by Option

Designation, Model Size,

Voltage, and P/N

CA1

CA1

CA2

CA3

CA1

CA2

CA3

CA1

CA2

CA3

115V 115V 208V 230V 115V 208V

230V 115V 208V 230V

98467 136862 135441 135442 98468 98469 98470 98471 98472 98473

Components

Qty

P/N

P/N

P/N

P/N

P/N

P/N

P/N

P/N

P/N

P/N

Venter Sub-assembly

1 97976 97976 97977 97978 97976 97977 97978 97955 97956 97957

Flue Adapter Assembly

1 97823

146094

97824

97825

Flexible Conduit 3/8" x 24"

2

19680

Parts Bag (see list below)

1

97966

P/N 97966 includes: The parts bag is standardized for all option kits. It contains

all items required for any installation and may include parts that do not apply to

your particular installation.

The parts highlighted should always be used.

Qty

P/N

Description

2

96386 Hanger Assembly

1

97943 Restrictor, 1" Wide

1

97944 Restrictor, 1-1/2" Wide

1

98664 Restrictor, 2" Wide

1

99665 Restrictor, 2-3/4" Wide

11

11813 Sheetmetal Screw, #10 x 1/2"

2

97941 Conduit Connector, Tinnerman #C54882-017

13

16354 Twist-on Wire Connector (orange), Ideal #3-0273

2

16355 Twist-on Wire Connector (yellow) (used for field connection on

Model B)

1

16199 Box Connector, T&B #253

1

1417 90° Box Connector

2

16358 Anti-Short Bushing (red)

1

98364 Brown Wire Assembly

1

38462 Blue Wire, 18 Gauge x 60", 105°C

1

91453 Orange Wire, 18 Gauge x 60", 105°C

1

38463 Yellow Wire, 18 Gauge x 60", 105°C

1

38464 Brown Wire, 18 Gauge x 60", 105°C

1

3841 Black Wire, 18 Gauge x 36", 105°C

1

87880 White Wire, 18 Gauge x 36", 105°C

2

148086 Open/Closed Bushing, Heyco #OCB-625 (black)

1

103171 Warning Label

FIGURE 1 - Power Venter Option

Venter

Sub-assembly

(factory-assembled

motor, venter wheel

and housing, air

flow switch, time

delay relay, and

junction box)

Conduit

* Flue Adapter Assembly for Size 125

is not the same as illustrated. Size 125

adapter assembly is a flat plate with

flanges and a 4" collar (See FIGURE 4B,

page 4).

Flue Adapter

Assembly

*

This manual is related to the following products: