1.0 General

1.1 General Information

Reznor

®

Model REC Evaporative Cooling Module is designed as a free standing mod-

ule with duct flanges for connection

upstream from an air moving device. The Model

REC cooling module may be connected to a Reznor indirect-fired makeup air system,

a Reznor

®

Model ADF, ADFH, or RDF direct-fired makeup air system, a Reznor

®

blower

cabinet, or to some other type of indirect-fired system or blower cabinet within the

allowable CFM range. Model REC is not recommended for connection to direct-fired

makeup air systems other than Reznor

®

Models ADF, ADFH, or RDF.

IMPORTANT: Do NOT connect a Model REC to a blow-through system.

NOTE: This product and these instructions are designed for use in an outdoor installa-

tion. The module may be adapted to an indoor makeup air application.

1.2 Warranty

For warranty information, refer to the warranty form included in the “Owner’s Enve-

lope”.

1.3 Installation

Preparation

Check List

Make certain the installation complies with all local, utility, and national building

and safety regulations and codes.

Check module for shipping damage. If damage is found, document the damage

with the transporting agency and immediately contact your Reznor Distributor.

Check base package against parts list below:

Description

40

50

60

70

80

90

180

360

Side Support

(2)107227

(4)107227

Front & Rear Support

(2)106086 (2)106087 (2)106088 (2)106089 (2)106090

(2)107235

(4)107235

Leg (2 pcs per leg)

(8)107236

(16)107236

Duct Connection Angle

(1)106095 (1)106096 (1)106097 (1)106098 (1)106099 (1)106100 (1)111501

(2)111501

Hardware: (10 each Sizes 40-180; 20 each Size 360) 1/4-20x3/4” Lg Cap Screw,

P/N 16246, and 1/4-20 Hex Nut, P/N 10650

In addition, the following parts for making electrical and water connections may be

shipped in the bottom pan of the evaporative cooling module.

REC Size and

Type of Media

40

50

60

70

80

90

180

360*

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

12” (305mm) cellulose

184 83 212 96 237 108 270 122 295 134 318 144 431 195 862 390

12” (305mm) glass fiber 201 91 230 104 261 118 296 134 305 138 350 159 514 233 1028 466
* A Size 360 is two separate Size 180 evaporative cooling modules.

Qty

P/N

Description

1

105945 1/4" Hose I.D. x 1/2" N.P.T. Bleed Line Fitting (not used with AquaSaver timed

metering system)

2

16835 Bushings, Heyco #SR-7W-2

If optional equipment will be field installed (Moisture Elimination Pads for Size 180

or 360 and/or a Drain and Fill or Freeze Protection Kit for any size), parts will be

shipped separately. Check to be sure that options are available for installation.

If the REC evaporative cooling module is being added to an existing makeup

air system, make certain that the system has sufficient motor capacity for the

increased static pressure. (See Appendix, page 12.)

Make certain the roof (or supporting structure) is capable of handling the additional

load of a cooling module with a full reservoir. (See weights in table.)

1.0 General ................................................................. 2

1.1 General Information ........................................2

1.2 Warranty ............................................................2

1.3 Installation Preparation Check List ................2

2.0 Dimensions .......................................................... 3
3.0 Mechanical ........................................................... 3

3.1 Assembly Instructions .....................................3

3.2 Water Flow Controls and Connections ..........5

5.0 Adjust Water Flow Over Media ........................... 8
4.0 Electrical Connections ....................................... 8

6.0 Maintenance and Service ................................... 9

6.1 Media Pads........................................................9

6.2 Water Feed Line & PVC Distribution Piping 10

6.3 Water Pump and Inlet Basket Screen ...........10

6.4 Troubleshooting Chart ..................................11

APPENDIX ................................................................ 11

Dimensions - Model REC 360 ..............................11

Cross-Reference Application Chart ....................11

Pressure Drop Table - REC Sizes 40-180 ...........12

Index ......................................................................... 12

INSTALLATION RECORD ....................................... 12

Table of Contents

Weight of Evaporative

Cooling Module with Wet

Media and Full Reservoir