PRG AutoPar User Manual 2.1 User Manual
Page 45
AUTOPAR
®
WASH LUMINAIRE USER MANUAL
37
Photometric Data
AutoPar Luminaire with MSR700 Lamp
* Multiply throw distance by Tn to determine coverage.
**To calculate center beam illuminance (I) at a specific distance (D):
-- if (D) is in feet, (I) is in foot candles
-- if (D) is in meters, (I) is in lux
LENS
CANDELA
(cd) **
BEAM ANGLE
(degrees)
BEAM
(Tn) *
FIELD ANGLE
(degrees)
FIELD
(Tn) *
VNSP
1,625,000
5°
0.087
14°
0.246
NSP
1,155,000
7.5°
0.131
15°
0.263
8-Row Horiz
360,000
18°
0.317
31°
0.555
8-Row Vert
360,000
12°
0.210
23°
0.407
12-Row Horiz
140,000
31°
0.555
50°
0.933
12-Row Vert
140,000
21°
0.371
33°
0.592
11.38"
(289 mm)
(122 mm)
4.80"
(257 mm)
10.12"
I =
cd
D
2