beautypg.com

PRG Best Boy 4000 User Manual User Manual

Page 63

background image

BEST BOY 4000

®

SPOT LUMINAIRE USER MANUAL

55

Gobo out of zero range

When zeroing gobo wheels, the wheel is
too far away from zero to set the position

Move wheel closer to home position
before zero command

Head Fan Error

Fan not running properly

Check fan

In Free Mode: Can’t Lock

Free mode is enabled

Use pan/tilt menu to change from "free"
to "lock"

Lamp Off

Fan Error: Cannot strike lamp while any
fan is in error state

Check fan, fan cabling

Lamp Off: Over Temperature

Head temperature too high

Check fans

Lamp over threshold

Lamp hours above recommended
maximum

Change lamp

Must Unlock via Free Option

Lock is enabled

Use pan/tilt menu to change from "lock"
to "norm"

Plenum Fan Error

Fan not running properly

Check fan

PMD Motion Error

Mechanism's actual position is too far
from its commanded position

Check mechanism motion

Framing Motor Disabled

Framing not running properly

Recalibrate, check mechanism motion

Stack Fan Error

One or more stack fans not running
properly

Check fan, fan cabling

Temp over threshold

Temperature too high

Check fans/filters

Tip Fan Error

Fan not running properly

Check fan

UPE Fans Error

Upper Enclosure fans not running
properly

Check fan, fan cabling

Yoke Fan Error

Fan not running properly

Check fan

Error Code

Explanation

Solution