BEST BOY 4000
®
SPOT LUMINAIRE USER MANUAL
Pan/Tilt Screen
+
Invert Pan / Invert Tilt - displays current invert settings. Press to
bring up Invert Yes/No options. When inverted, pan/tilt will move in
the opposite direction.
+
Swap - displays current swap setting. Press to bring up Swap Pan/
Tilt Yes/No options. When swapped, the pan channel will control tilt
and vice versa.
+
Free - displays the current "free" setting. Press to bring up Yes/No
options. Yes will enable "free" control, which allows the luminaire to
be used as a follow spot.
+
Lock Pan/Tilt - displays current lock setting. Press to bring up Lock
Yes/No options. When locked, a mechanism will not release brake
or calibrate, only remain in its fixed position.
Once configured, any Pan/Tilt settings will be displayed in the CONFIG
panel of the Home screen as shown in the example to the right.
Press (X) to return to
Communication Screen
+
Control - displays current DMX512 control values. Values will be
highlighted in green when changing.
+
Info - displays current source (DMX512 or Art-Net/Ethernet),
number of bytes in the frame, update rate, and universe number (if
Art-Net). Press INFO to bring up the Comm Stats screen.
+
Comm Loss - configures how long to wait before the fixture fades
to black upon loss of comm data. Press COMM LOSS to bring up
"Set Trigger Fade After" option. Set to No Fade, 30 Seconds or 60
Seconds. (Also refer to
"Configuring Comm Loss Setting"
Press (X) to return to
Status Screen
+
Mechanisms - displays mechanism status. Mechanism names will
be shown in yellow while calibrating, then change to green if okay or
red if an error exists. Locked mechanisms will be shown in white.
Press to bring up Test Screen.
+
Log - displays system status log. The log entries are stored in
persistent memory and are retained through power down. Use
touchscreen arrows to scroll up or down. Press CLR to bring up
Clear Log Yes/No options.
Press (X) to return to
Pan/Tilt Screen
Comm Screen
Comm Stats Screen
Status Screen