Comm led operation, Bypassing calibration – PRG Best Boy 4000 User Manual User Manual
Page 32

24
BEST BOY 4000
®
SPOT LUMINAIRE USER MANUAL
Comm LED Operation
The Comm LED - located on the upper enclosure connector panel - indicates system control status. This can be used
determine if the luminaire is receiving a control signal. LED indications are as follows:
Figure 2-14: Comm LED
+
Green - The Comm LED will light
green
if either DMX or Ethernet control is present. Note that if both valid DMX
and Ethernet control are being received, DMX control will take precedence.
+
Yellow - The Comm LED will blink
yellow
if there is an error.
+
Red - The Comm LED will light
red
if no DMX or Ethernet is present.
Bypassing Calibration
If the menu screen is touched (in the center) and held during startup, the luminaire will present a menu that provides
the option to bypass calibration. This feature allows the luminaire to skip the calibration sequence so that it can be
powered up in the case for configuration purposes.
To bypass calibration:
Step
1. Connect power to luminaire.
Step
2. At startup, touch center of menu screen and hold until Bypass
Calibration menu appears.
Step
3. Press
Yes
to bypass calibration. (The menu will automatically
dismiss if no selection is made within 5 seconds.)
Step
4. Proceed with programming of starting address or other
options.
100 -240 VAC
12A Max
50 / 60 Hz
IN
DMX
THRU
ETHERNET
AC IN
COMM
WAKE
Comm LED