beautypg.com

Troubleshooting, Troubleshooting guide – PRG Best Boy 4000 User Manual User Manual

Page 60

background image

52

BEST BOY 4000

®

SPOT LUMINAIRE USER MANUAL

TROUBLESHOOTING

Troubleshooting Guide

The following table provides a list of common start-up problems and possible solutions.

Symptom

Solution(s)

Refer to...

No power to luminaire.

Ensure power cable is properly connected to Neutrik
input connector.

page 10

Ensure power is switched on at source (mains,
disconnect box, etc.)

n/a

No console control.

Ensure DMX512 or Ethernet data cable is properly
connected.

page 21

Ensure DMX512 address setting is correct.

page 25

DMX512 control not working
correctly throughout daisy-chain.

Ensure data cables are correctly configured.

page 21

Ensure termination connector is installed at last
luminaire in data link.

page 12

Lamp does not strike at power-up.

Configure lamp to start at power-up.

page 33

Comm LED is red indicating that no
valid DMX or Ethernet signal is
detected.

Ensure DMX512 or Ethernet data cable is properly
connected.

Check console.

page 21

No Ethernet control.

Ensure that luminaire is not also receiving a DMX
signal. If both valid DMX and Ethernet control are
being received, DMX control will take precedence.

page 24

Beam obstructed by gobo in open
position.

Set new gobo zero position.

page 50

Luminaire won’t take software
update.

Remove active control (DMX512 or Art-Net).

page 61

Light spill occurring at some zoom
angles.

Engage Light Shield.

page 20

Comm LED flashing red or green.

Indicates an internal error on the fixture. Check Status
screen to isolate.