The first phase of operation is the high‐gain initialization phase. During the initialization phase, the unit is expected
to be stationary or quasi‐static so the EKF weights the accelerometer gravity reference and Earth’s magnetic field
reference heavily in order to rapidly estimate the X, Y, and Z rate sensor bias, and the initial attitude and heading of
the unit. The initialization phase lasts approximately 60 seconds, and the initialization phase can be monitored in
the software Status BIT transmitted by default in each measurement packet. After the initialization phase, the unit
operates with lower levels of feedback (also referred to as EKF gain) from the accelerometers and magnetometers to
continuously estimate and correct for roll, pitch, and heading (yaw) errors, as well as to estimate X, Y, and Z rate
sensor bias.
The AHRS440provides the same scaled sensor and angle mode packets of the VG440. The AHRS440 defaults to the
A1 Angle Packet which outputs the roll angle, pitch angle, yaw angle, and digital IMU440data. In the AHRS440, the
A0
and A1 packets contain accurate magnetometer readings. Refer to Chapter 9. Communicating with the 440 and
Chapter 10. Programming Guidelines for full packet descriptions.
performance degradation. Refer to Chapter 4. Magnetometer Calibration and Alignment Guidelines for
information about magnetic calibration; review that information before using the AHRS440.
NOTE: The unit must be mounted at least 24” away from large ferrous objects and fluctuating magnetic fields.
Failure to locate the unit in a clean magnetic environment will affect the attitude solution.
AHRS440 Advanced Settings
In addition to the configurable baud rate, packet rate, axis orientation, and sensor low‐pass filter settings, the unit
provides additional advanced settings which are selectable for tailoring the unit to specific application
requirements. The AHRS440 advanced settings are listed in
below:
Table 7AHRS 440 Series Advanced Settings
Setting
Default Value
Comments
Baud Rate
38400
9600, 19200, 57600 also available
Packet Type
A1
S0, S1, S2, A0, A2, N0, N1 also available
Packet Rate
25 Hz
This setting sets the rate at which selected Packet Type, packets are output. If
polled mode is desired, then select Quiet.
Orientation
See Figure 4 on
page 22.
To configure the axis orientation, select the desired measurement for each axis:
NAV‐VIEW 2.2 will show the corresponding image of the unit, so it easy to
visualize the mode of operation. Refer to Orientation Field on page 84 for the
twenty four possible orientation settings. The default setting points the
connector AFT.