M1966_onh_nopoh_detect, M1966_onh_polarity_chg, M1966_ofh_polarity_chg – Maxim Integrated 73M1866B/73M1966B Reference Driver User Manual
Page 17

UG_1x66B_015
73M1866B/73M1966B Reference Driver User Guide
Rev. 2.7
17
5.2.4 M1966_ONH_NOPOH_DETECT
This event is generated when a parallel phone goes back on hook while the FXO line is in on-hook state.
Parameters
Data Type
Name
Description
unsigned int
event_id
M1966_ONH_NOPOH_DETECT
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.5 M1966_ONH_POLARITY_CHG
This event is generated when there is a voltage reversal occurs on the line while in on-hook state.
Parameters
Data Type
Name
Description
unsigned int
event_id
M1966_ONH_POLARITY_CHG
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.6 M1966_OFH_POLARITY_CHG
This event is generated when there is a voltage reversal occurs on the line while in off-hook state.
Parameters
Data Type
Name
Description
unsigned int
event_id
M1966_OFH_POLARITY_CHG
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.