beautypg.com

2 event identification, Event identification, M1966_battery_dropped – Maxim Integrated 73M1866B/73M1966B Reference Driver User Manual

Page 16: M1966_battery_feeded, M1966_onh_apoh_detect, Section 5.2

background image

73M1866B/73M1966B Reference Driver User Guide

UG_1x66B_015

16

Rev. 2.7

5.2 Event Identification

5.2.1 M1966_BATTERY_DROPPED

This event occurs when the FXO line is disconnected from the telephone network.

Parameters

Data Type

Name

Description

unsigned int

event_id

M1966_BATTERY_DROPPED

.

unsigned int

channel_id

Channel ID.

unsigned int

event_cnt

Number of events that remain in the queue.

unsigned int

event_data1

N/A.

unsigned int

event_data2

N/A.

unsigned int

event_data3

N/A.

unsigned int

event_data4

N/A.

5.2.2 M1966_BATTERY_FEEDED

This event is generated when the line is connected to the telephone network and the voltage is restored
to normal operating level.

Parameters

Data Type

Name

Description

unsigned int

event_id

M1966_BATTERY_FEEDED

.

unsigned int

channel_id

Channel ID.

unsigned int

event_cnt

Number of events that remain in the queue.

unsigned int

event_data1

N/A.

unsigned int

event_data2

N/A.

unsigned int

event_data3

N/A.

unsigned int

event_data4

N/A.

5.2.3 M1966_ONH_APOH_DETECT

This event is generated when a parallel phone goes off hook while the FXO line is in on-hook state.

Parameters

Data Type

Name

Description

unsigned int

event_id

M1966_ONH_APOH_DETECT

.

unsigned int

channel_id

Channel ID.

unsigned int

event_cnt

Number of events that remain in the queue.

unsigned int

event_data1

N/A.

unsigned int

event_data2

N/A.

unsigned int

event_data3

N/A.

unsigned int

event_data4

N/A.