Instruction manual tn_us, Sauter gmbh – KERN & SOHN TN 300-0.01US User Manual
Page 7

Sauter GmbH
Tieringerstr. 11-15
D-72336 Balingen
E-Mail: [email protected]
Tel: +49-[0]7433- 9976-174
Fax: +49-[0]7433-9976-285
Internet: www. sauter.eu
Instruction Manual
TN_US
TN_US-BA-e-1112
7
4.8.2 Clearing a selected file
It may be required to clear the contents of an entire file
completely of all measurements. With this a new list of
measurements can be stared, beginning with L00.
The procedure is outlined in the following steps:
1) The key
is to be pressed to activate the data logging
functions. The current file name and the total record
. count of the file will be displayed.
2) The key
and the key
have to be used to scroll to
the file that shall be cleared of all measurements.
3) The
key has to be pressed on the desired file. The
file will be automatically cleared and display “-DEL”.
4) The key
has to be pressed to exit the data logging
functions any time as wanted to return to the measure-
ment mode.
4.8.3 Viewing/ deleting stored records
With this function a record can be viewed/ deleted in a
desired file previously saved in memory, following these
steps:
1) The key
is to be pressed to activate the data logging
functions. The current file name and the total record
. count of the file will be displayed.
2) The key
and the key
have to be used to select
the desired file.
3) The
key has to be pressed to enter the selected file.
The current record number will be displayed (i.e. L012)
and as well the record contents.
4) The key
and the key
have to be used to select
the desired record.
5) The
key has to be pressed on the desired record.
This record will be automatically deleted and “-DEL” is
displayed.
6) The key
has to be pressed to exit the data logging
functions to return to the measurement mode.
4.9 Data printing
At the end of the inspection process or at the end of the
day, it may be required the readings being transferred to a
computer. This procedure is only possible with
TN xx-0.01 US, not with TN xx-0.1 US:
1. Before printing, one connection plug of the print cable
(optional parts) has to be inserted into the socket on the
up-left of the main body and the other plug into the
communication socket of the mini-printer.
2. The
key has to be pressed to activate the data
logging functions.
3. The key
and the key
have to be used to select
the desired file.
4. The
key has to be pressed to print the selected file.
With this operation all the data in the current file will be
sent to the mini-printer via RS-232 port and will be
printed.
5. The
key has to be pressed to exit the data logging
functions to return to the measurement mode.
4.10 Beep- Mode
When the beep is set to ((On)), a short hoot will be heard
each time while pressing the key, on each measurement or
if the measured value exceeds the tolerance limit.
The
key has to be pressed to switch the Beep-Mode
on and off. The current Beep-Mode will be displayed.
4.11 EL Backlight
With the background light, it is convenient to work in even
dark condition. The
key has to be pressed to switch on
or off the background light any moment it is needed after
having powered on the instrument.
As the EL light will consume much power it only has to be
turned on if necessary.
4.12 Battery information
Two AA size alkaline batteries are needed as power
source. After several hours’ usage of the preset batteries,
the battery symbol on the screen will be shown as
.
If battery capacity runs out, the battery symbol
will
be shown and it will begin to flash. In this case, the
batteries should be replaced.
If the instrument isn’t used for a longer period, the batteries
have to be removed.
4.13 Auto Power off
The instrument features an “auto power off”- function
designed to conserve battery life. If it is not in use for 5
minutes or more, it will turn itself off. If the voltage of the
battery is too low this function will also work.
4.14 System reset
The
key has to be pressed while powering on the
instrument: factory defaults will be restored.
All the memory data will be cleared during system reset.
The only time this might be helpful is if the parameter in
the instrument was somehow corrupted.
4.15 Connection to PC
TN xx-0.01 US is equipped with a RS-232serial port. Using
the accessory cable, the instrument has got the ability to
connect to a PC or an external storage device.
Measurement data stored in the memory can be
transferred to the PC through the RS-232 port. For detailed