beautypg.com

8 menu mode description – Citizen Systems Citizen CLP 8301 CLP-8301 User Manual

Page 61

background image

Chapter 6 Configuring Your Printer Using the Menus

48

6.8 Menu Mode Description

Group Menu

Menu Item

Default Value

Range of Values

Description

Label Width

8.53in
216.7mm

3.00

8.64in

76.2

219.5mm

Set the maximum limit for the
printable width. Image or data
beyond this limit will not be printed.

Note:

The actual printable area is split equally either side of the centerline of the media, e.g. 8.20” would
print from 4.1” to the left of center to “4.1” to right of the centerline.


Printing Speed

04 IPS

02

04 IPS

Set print speed.

Print Darkness

10

00

30

Set print darkness by controlling
printhead heat.

Note:

When language is “DPP,” the maximum value is 20.


Print Method

TT

DT / Direct Thermal
TT / Thermal Transfer

Set printing method.

Ribbon Torque

3

1

5

Set ribbon winding torque.

Note:

If smudge occurs, increase the value. When a small width of label is used, decrease the value.


Continu. MediaLen

4.00in
101.6mm

0.25

40.00in

6.4

1016.0mm

Set media length for print in Sensor
None mode.

Note:

The maximum media length will be changed by using the “Label Width” value due to allocation
of RAM memory space for print data. When media widths are 0

4.2in, 4.21

6.2in and 6.21in

or more, the values are 40in (1016mm), 30in (762mm) and 20in (508mm) respectively.


Vertical Position

0.00in
0.00mm

- 1.00

1.00in

-25.4

25.4mm

Adjust print start position in vertical
direction.

*Page Setup

Horizont Shift

0.10in
2.5mm

- 1.00

1.00in

-25.4

25.4mm

Adjust print start position in horizontal
direction

Media Sensor

See Thru

See Thru
Notch
Reflect
None

Select label sensor.
See Thru: Transparent GAP sensor.
Notch: Transparent HOLE sensor.
Reflect: Reflective sensor.
None: No use of sensor (continuous
media)

Sensor Monitor

x.xV adc

LCD display shows media sensing
level while setting media in the
sensor position.
When None, See Thru (Gap) sensor
sensing level is monitored.

Note:

a)

Before performing Sensor Monitor, ensure that Media Sensor selection is matched correctly
with media.

b)

The average sensor value between the label a nd liner area is recommended to use for
setting the “Sensor Level” (see below).

c)

When Media Sensor is set to None, See Thru (Gap) sensor is monitored.


Sensor Level

1.5V/1.7V

0.0V

3.3V

Set threshold value for media sensor
by changing Up or Down key.

* System Setup

Note:

For reflective sensor, if black marks on the liner are not detected because of small reflection
factor, decrease the sensor level. For transparent sensor, if notches or gaps between labels
are not detected because of small transparency factor, decrease the sensor level. The Sensor
Monitor menu will be useful for setting Sensor Level.

(continued)