Performance data sheet (con’t) – Culligan Aqua-Cleer Advanced Drinking Water Systems User Manual

Page 43

background image

4

AS3
The AS has been tested according to NSF/ANSI 5 for the reduction of the substances

listed below. The concentration of the indicated substances in the water entering the

system was reduced to a concentration less than or equal to the permissible limit for

water leaving the system, as specified in NSF/ANSI 5. Conforms to NSF/ANSI Standard

5 for arsenic (trivalent and pentavalent) reduction. See Arsenic Fact section for an

explanation of reduction performance.

Substance Removal

1

Substance

Influent Challenge

Concentration

mg/L

Maximum

Permissible

Product water

Concentration mg/L

Reduction

Require-

ments

Minimum

Reduction

Average

Reduction

Standard 5
Trivalent

Arsenic pH 6.5

0.050 + 10%

0.010

94.9%

Trivalent

Arsenic pH 8.5

0.050 + 10%

0.010

98.0%

Pentavalent

Arsenic

0.050 + 10%

0.010

97.4%

Flow Rate = 0.05 gpm (0.1 Lpm)

Capacity = 1000 gallons (786 L)

1000 gallon capacity is only for use with PID

Testing was performed under standard laboratory conditions, actual performance may vary.

PER*
The PER has been tested for perchlorate reduction with an average influent of 10 ug/L

and an average effluent of <1ug/L as tested by NSF International.

Substance Removal

1

Substance

Influent Challenge

Concentration

mg/L

Maximum

Permissible

Product water Con-

centration mg/L

Reduction

Require-

ments

Minimum

Reduction

Average

Reduction

Perchlorate

0.10 + 10%

0.006

99.0%

Flow Rate = 0.05 gpm (0.1 Lpm)

Capacity = 1000 gallons (786 L)

Testing was performed under standard laboratory conditions, actual performance may vary.

* Cartridge not for sale in California.

Performance

Data Sheet

(con’t)