beautypg.com

Performance data sheet (con’t) – Culligan Aqua-Cleer Advanced Drinking Water Systems User Manual

Page 42

background image

42

Performance

Data Sheet

(con’t)

Output (Total Dissolved Solids (TDS) Reduction and Output Production)

1

RO30

Tank Size

2 gallon

3 gallon

9 gallon

Product System Daily Prod. Rate To Pressurized Storage

Tank

11.09 gpd 11.09 gpd 11.09 gpd

Prod. Rate without Storage Tank To Atmosphere

6 gpd

6 gpd

6 gpd

Efficiency Rating

2

16.86%

16.86%

16.86%

Recovery Rating

28.84%

28.84%

28.84%

Influent Challenge Concentration (Mg/L)

770

770

770

Max. Permissible Product Water Concentration (Mg/L)

187

187

187

Minimum Percent Removal

9.1%

9.1%

9.1%

Average Percent Removal

95.4%

95.4%

95.4%

1 This is a factory specification for membrane production. Actual production rate and TDS rejection will depend on temperature, water pressure, TDS

level, membrane variation and usage pattern.

2 Efficiency rating means the percentage of the influent water to the system that is available to the user are reverse osmosis treated water under

operating conditions that approximate daily usage.

3 Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis

treated water when the system is operated without a storage tank or when the storage tank is bypassed.

Output (Total Dissolved Solids (TDS) Reduction and Output Production)

1

RO50

Tank Size

2 gallon

3 gallon

9 gallon

Product System Daily Prod. Rate To Pressurized Storage

Tank

16.16 gpd 16.16 gpd 16.16 gpd

Prod. Rate without Storage Tank To Atmosphere

50 gpd

50 gpd

50 gpd

Efficiency Rating

2

18.98%

18.98%

18.98%

Recovery Rating

1.7%

1.7%

1.7%

Influent Challenge Concentration (Mg/L)

770

770

770

Max. Permissible Product Water Concentration (Mg/L)

187

187

187

Minimum Percent Removal

86.6%

86.6%

86.6%

Average Percent Removal

92.%

92.%

92.%

1 This is a factory specification for membrane production. Actual production rate and TDS rejection will depend on temperature, water pressure, TDS

level, membrane variation and usage pattern.

2 Efficiency rating means the percentage of the influent water to the system that is available to the user are reverse osmosis treated water under

operating conditions that approximate daily usage.

3 Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis

treated water when the system is operated without a storage tank or when the storage tank is bypassed.

Testing Conditions (Complete System)

Temperature: 77º F + 2º F

pH: 7.5 + 0.5

Pressure: 50 psi

Turbidity: <1 NTU

This system has been tested and shown to operate at its calculated recovery rating under

standard laboratory conditions.
This reverse osmosis system contains a replaceable component critical to the efficiency

of the system. Replacement of the reverse osmosis component should be with one of

identical specifications, as defined by the manufacturer, to assure the same efficiency and