beautypg.com

Performance data sheet (con’t) – Culligan Aqua-Cleer Advanced Drinking Water Systems User Manual

Page 20

background image

20

Total Defense (TD)
The Total Defense has been tested according to NSF/ANSI 42 and 5 for the reduction of

the substances listed below. The concentration of the indicated substances in the water

entering the system was reduced to a concentration less than or equal to the permissible

limit for water leaving the system, as specified in NSF/ANSI 42 and 5.

Substance Removal

1

Substance

Influent

Challenge

Concentration

mg/L

Maximum

Permissible

Product

water Con-

centration

mg/L

Reduction

Require-

ments

Minimum

Reduction

Average

Reduction

Standard 42
Chlorine

2.0 mg/L + 10%

>50%

97.6%

98.0%

Chloramines

.0 mg/L + 10% 0.5 mg/L

97.6%

98.0%

Particulate

(0.5 - < um) Class I

at least 10,000

particles/mL

>85%

99.9%

99.9%

Standard 5
MTBE

0.015 + 20%

0.005 mg/L

74.6%

8.%

Cyst

t

Minimum

50,000/L

99.95%

99.99%

99.99%

Turbidity

11 mg/L + 1

NTU

0.5 NTU

96.6%

98.0%

Lead

(pH 6.5)

0.15 mg/L +

10%

0.010 mg/L

99.%

99.%

Lead

(pH 8.5)

0.15 mg/L +

10%

0.010 mg/L

99.%

99.%

Mercury

(pH 6.5)

0.006 mg/L +

10%

0.002 mg/L

96.6%

96.6%

Mercury

(pH 8.5)

0.006 mg/L +

10%

0.002 mg/L

72.4%

95.4%

Chloroform (VOC surro-

gate chemical)

0.00 mg/L +

10%

0.015 mg/L

95.2%

91.0%

Flow Rate = 0.5 gpm (1.89 Lpm)

Capacity = 1,000 gallons (786 L)

t Based on the use of microspheres or Cryptosporidium parvum oocysts

Testing was performed under standard laboratory conditions, actual performance may vary

Organic Chemicals Included in Surrogate Testing:

Applies to Total Defense (TD) only

Performance

Data Sheet