This system has been tested according to NSF/ANSI 58 for the reduction of the

substances listed below. The concentration of the indicated substances in water entering

the system was reduced to a concentration less than or equal to the permissible limit for

water leaving the system, as specified in NSF/ANSI 58.

This system is acceptable for treatment of influent concentrations of no more than 27 mg/L

nitrate and mg/L nitrite in combination measured as N and is certified for nitrate/nitrite

reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater.

Substance Removal

1

Substance

Influent

Challenge

Concentration

mg/L

Maximum

Permissible

Product

water Con-

centration

mg/L

Reduction

Require-

ments

Minimum

Reduction

Average

Reduction

Arsenic (Pentavalent)

2

0.050 +/- 10%

0.01

97.4%

Barium

10.0 +/- 10%

2

9.8%

Cadmium

0.0 +/- 10%

0.005

98.7%

Hexavalent Chromium

0.0 +/- 10%

0.05

91.2%

Trivalent Chromium

0.0 +/- 10%

0.05

94.8%

Copper

.00 +/- 10%

1.

98.9%

Fluoride

8.0 +/- 10%

1.5

95.6%

Lead

0.15 +/- 10%

0.010

98.7%

Nitrate/Nitrite

(both as N)

0 +/- 10%

82.8%

86.4%

Nitrate

5

27.0 +/- 10%

10.0

82.7%

86.5%

Nitrite

.0 +/- 10%

1.0

80.9%

84.7%

Radium 226/228

25pCi/L +/- 10% 5pCi/L

80.0%

Selenium

0.10 +/- 10%

0.05

96.0%

Cyst

4

>50,000/mL

99.95%

99.99%

99.99%

Turbidity

11 +/- 1 NTU

0.5 NTU

99.00%

1 While testing was performed under standard laboratory conditions, actual performance ay vary depending on water pressure, temperatures and

other substances, which may be found in your water.

2 This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations

of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water

supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pen-

tavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent

arsenic. Please see the Arsenic Facts Sheet for further information.

Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.

4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.

5 Units are not certified on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.