Performance data sheet (con’t) – Culligan Aqua-Cleer Advanced Drinking Water Systems User Manual
Page 39
9
Total Defense (TD)
Total Defense has been tested according to NSF/ANSI 42 and 5 for the reduction of the substances
listed below. The concentration of the indicated substances in the water entering the system was
reduced to a concentration less than or equal to the permissible limit for water leaving the system,
as specified in NSF/ANSI 42 and 53.
Substance Removal
1
Substance
Influent
Challenge
Concentration
mg/L
Maximum
Permissible
Product
water Con-
centration
mg/L
Reduction
Require-
ments
Minimum
Reduction
Average
Reduction
Standard 42
Chlorine
2.0 mg/L + 10%
>50%
97.6%
98.0%
Chloramines
.0 mg/L + 10%
0.5 mg/L
97.6%
98.0%
Particulate
(0.5 - < um) Class I
at least 10,000
particles/mL
>85%
99.9%
99.9%
Standard 5
MTBE
0.015 + 20%
0.005 mg/L
69%
74.6%
8.%
Cyst t
Minimum
50,000/L
99.95%
99.95%
99.99%
Turbidity
11 mg/L + 1
NTU
0.5 NTU
96.6%
98.0%
Lead (pH 6.5)
0.15 mg/L +
10%
0.010 mg/L
99.%
99.%
Lead (pH 8.5)
0.15 mg/L +
10%
0.010 mg/L
99.%
99.%
Mercury (pH 6.5)
0.006 mg/L +
10%
0.002 mg/L
96.6%
96.6%
Mercury (pH 8.5)
0.006 mg/L +
10%
0.002 mg/L
72.4%
95.4%
Chloroform (VOC sur-
rogate chemical)
0.00 mg/L +
10%
0.015 mg/L
95.2%
91.0%
Flow Rate = 0.5 gpm (1.89 Lpm)
Capacity = 1,000 gallons (786 L)
t Based on the use of microspheres or Cryptosporidium parvum oocysts
Testing was performed under standard laboratory conditions, actual performance may vary
Organic Chemicals Included in Surrogate Testing:
Applies to Total Defense (TD) only
Performance
Data Sheet
(con’t)