Total Defense (TD)

The Total Defense has been tested according to NSF/ANSI 42 and 5 for the reduction of

the substances listed below. The concentration of the indicated substances in the water

entering the system was reduced to a concentration less than or equal to the permissible

limit for water leaving the system, as specified in NSF/ANSI 42 and 5.

Substance

Influent

Challenge

Concentration

Maximum

Permissible

Product water

Concentration

Reduction

Requirements

Minimum

Reduction

Average

Reduction

Standard 42
Chlorine

2.0 mg/L + 10%

>50%

97.6%

98.0%

Chloramines .0 mg/L + 10%

0.5 mg/L

97.6%

98.0%

Particulate

(0.5 - < um)

Class I

At least 10,000

particles/mL

>85%

99.9%

99.9%

Standard 5
MTBE

0.015 + 20%

0.005 mg/L

74.6%

8.%

Cyst

t

Minimum

50,000/L

99.95%

99.99%

99.99%

Turbidity

11 mg/L + 1

NTU

0.5 NTU

96.6%

98.0%

Lead

(pH 6.5)

0.15 mg/L +

10%

0.010 mg/L

99.%

99.%

Lead

(pH 8.5)

0.15 mg/L +

10%

0.010 mg/L

99.%

99.%

Mercury

(pH 6.5)

0.006 mg/L +

10%

0.002 mg/L

96.6%

96.6%

Mercury

(pH 8.5)

0.006 mg/L +

10%

0.002 mg/L

72.4%

95.4%

Chloro-

form (VOC

surrogate

chemical)

0.00 mg/L +

10%

0.015 mg/L

95.2%

91.0%

Flow Rate = 0.5 gpm (1.89 Lpm)

Capacity = 1,000 gallons (786 L)

t Based on the use of microspheres or Cryptospordium parvum oocysts

Testing was performed under standard laboratory conditions, actual performance may vary.