Performance data sheet (con’t) – Culligan Aqua-Cleer Advanced Drinking Water Systems User Manual
Page 15
15
Total Defense (TD)
The Total Defense has been tested according to NSF/ANSI 42 and 5 for the reduction of
the substances listed below. The concentration of the indicated substances in the water
entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 42 and 5.
Substance
Influent
Challenge
Concentration
Maximum
Permissible
Product water
Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42
Chlorine
2.0 mg/L + 10%
>50%
97.6%
98.0%
Chloramines .0 mg/L + 10%
0.5 mg/L
97.6%
98.0%
Particulate
(0.5 - < um)
Class I
At least 10,000
particles/mL
>85%
99.9%
99.9%
Standard 5
MTBE
0.015 + 20%
0.005 mg/L
74.6%
8.%
Cyst
t
Minimum
50,000/L
99.95%
99.99%
99.99%
Turbidity
11 mg/L + 1
NTU
0.5 NTU
96.6%
98.0%
Lead
(pH 6.5)
0.15 mg/L +
10%
0.010 mg/L
99.%
99.%
Lead
(pH 8.5)
0.15 mg/L +
10%
0.010 mg/L
99.%
99.%
Mercury
(pH 6.5)
0.006 mg/L +
10%
0.002 mg/L
96.6%
96.6%
Mercury
(pH 8.5)
0.006 mg/L +
10%
0.002 mg/L
72.4%
95.4%
Chloro-
form (VOC
surrogate
chemical)
0.00 mg/L +
10%
0.015 mg/L
95.2%
91.0%
Flow Rate = 0.5 gpm (1.89 Lpm)
Capacity = 1,000 gallons (786 L)
t Based on the use of microspheres or Cryptospordium parvum oocysts
Testing was performed under standard laboratory conditions, actual performance may vary.
Performance
Data Sheet
(con’t)