beautypg.com

How to maintain your system (con’t) – Culligan Aqua-Cleer Advanced Drinking Water Systems User Manual

Page 12

background image

12

Preliminary Steps:
1. Check for any leaks that may exist from tubing connections or the faucet.
2. Check for flow to the drain. If flowing, close tank shut-off so you can check auto shut-off

operation

. Test and record product TDS from faucet. Also observe if faucet stem is stiff to move.
4. Test and record feed TDS, and then calculate rejection percentage.
5. If rejection is acceptable - Shut off storage tank, remove tank supply tubing to collect

and record product flow, and water temperature.

6. Record feed pressure if needed by attaching a pressure gauge to feed line. Use the

recorded feed pressure and water temperature to check product flow rate against the

supplied chart. Membrane okay? Low production could be the result of partially plugged

prefilters. If so retest after filters are changed.

7. With feed line off begin draining tank.

The Aqua-Cleer RO manifold assembly may be sanitized with 5-1/4% liquid chlorine

unscented bleach.

1. Shut off water supply then remove all filters. Put bypass plugs in ports 2, and 4.
2. Pour two tablespoons liquid chlorine bleach into the sanitizer cartridge and place in

port 1.

. Turn on the water supply valve and the RO faucet to allow the system to fill with

water. Allow the water to flow through until the entire system for about 10 minutes

or until the sanitizing solution is through.

4. Install new filters, including the post carbon filter, and membrane if needed, or

reuse existing membrane. Some filters require flushing before use to remove dust

and fines. If an in-plant flush was not performed, use the single head assembly to

perform this using the feed line and drain lines available. Don’t flush using the

RO manifold.

5. Replace the battery in the quality monitor if applicable.
6. Discard the first glass of water from the faucet.
7. Thoroughly check for leaks.

Item

Description

1

Manifold Assembly

2

5 Micron Sediment Filter
10 Micron Sediment Filter
25 Micron Sediment Filter

3

Carbon Block Filter
Granular Activated Carbon Filter

4

30 GPD Reverse Osmosis Membrane
50 GPD Reverse Osmosis Membrane
Nanofiltration Reverse Osmosis Membrane*=

5

Arsenic Filter
Perchlorate Filter**
Carbon Block Filter (MTBE, VOC)

6

Post Carbon Filter

7

Flow Control

8

Automatic Shut-off Valve

9

Faucet

10

2 Gallon Storage Tank
3 Gallon Storage Tank
9 Gallon Storage Tank

11

Ball Valve

*Monitor (Not Shown)

**Cartridges not for sale in California

=

Cartridge not for sale in California or Iowa

How to

Maintain Your

System (con’t)