beautypg.com

Performance data sheet (con’t) – Culligan Aqua-Cleer Advanced Drinking Water Systems User Manual

Page 31

background image

1

Performance

Data Sheet

(con’t)

RO50 with TD
These systems have been tested and certified by NSF International according to NSF/ANSI

42, 5, and 58 for the reduction of the substances listed below. The concentration of the

indicated substances in water entering the system was reduced to a concentration less

than or equal to the permissible limit for water leaving the system, as specified in

NSF/ANSI 42, 5, and 58.

Substance Removal

1

Substance

Influent Challenge

Concentration

mg/L

Maximum

Permissible

Product water

Concentration

mg/L

Reduction

Require-

ments

Minimum

Reduction

Average

Reduction

Arsenic (pen-

tavalent)2

0.0 +/- 10%

0.01

Barium

10.0 +/- 10%

2

9.8%

Cadmium

0.0 +/- 10%

0.005

98.7%

Hexavalent

Chromium

0.0 +/- 10%

0.05

91.2%

Trivalent Chro-

mium

0.0 +/- 10%

0.05

94.8%

Copper

.00 +/- 10%

1.

98.9%

Fluoride

8.0 +/- 10%

1.5

95.6%

Lead

0.15 +/- 10%

0.010

98.7%

Nitrate/Nitrite

(both as N)

0 +/- 10%

8.1%

86.8%

Nitrate5

27.0 +/- 10%

10.0

8.4%

87.0%

Nitrite

.0 +/- 10%

1.0

79.5%

84.8%

Radium

226/228

25pCi/L +/- 10%

5pCi/L

80.0%

Selenium

0.10 +/- 10%

0.05

96.0%

Cyst4

>50,000/mL

99.95%

99.98%

99.98%

Turbidity

11 +/- 1 NTU

0.5 NTU

99.00%

1 While testing was performed under standard laboratory conditions, actual performance ay vary depending on water pressure, temperatures and

other substances, which may be found in your water.

2 This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations

of 0.0 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water sup-

plies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent

arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic.

Please see the Arsenic Facts Sheet for further information.

Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.

4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.

5 Units are not certified on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended..