Technical Specifications

A-7

Figure A-2. EPIM-100FX

Specifications for the EPIM-100FX are listed in Table A-6. The
transmitter power levels and receive sensitivity levels listed are
peak power levels after optical overshoot. A peak power meter
must be used to correctly compare the values given above to those
measured on any particular port. If power levels are being
measured with an average power meter, add 3 dBm to the
measurement to compare the measured values to the values listed
below.

Table A-6. Transmitter Power

Cable Type

Worst Case Budget

Typical Budget

50/125 µm fiber

6.0 dB

9.0 dB

62.5/125 µm fiber

9.0 dB

12.0 dB

100/140 µm fiber

15.0 dB

18.0 dB

10X 12X 14X 16X

9X 11X 13X 15X

EPIM100

EPIM100

EPIM-100FX

LNK

EPIM-100FX

LNK