beautypg.com

Cabletron Systems SmartSTACK 100 User Manual

Page 45

background image

Unpacking and Installing Your ELS100-16TX

2-13

Figure 2-7. EPIM-100FX Port

4. Verify that a Link exists by checking that the port LINK LED is

solid green. If the LINK LED is off, perform the following
steps until it is on:

a. Check that the power is turned on for the device at the

other end of the Link.

b. Verify proper crossing over of fiber strands between the

applicable port on the ELS100-16TX and the fiber optic
device at the other end of the fiber optic link segment.

c. Verify that the fiber connection meets the dB loss

specifications.

If a Link has not been established, contact Cabletron Systems
Global Call Center. Refer to Section 1.2, Getting Help, for details.

The ELS100-16TX is now ready to be set up through Local
Management. Refer to Chapter 4, Monitoring and Managing Your
ELS100-16TX

, to configure the ELS100-16TX.

10X 12X 14X 16X

9X 11X 13X 15X

EPIM100

EPIM100

EPIM-100FX

LNK

EPIM-100FX

LNK