beautypg.com

9 rs232 – IC Realtime Max Series: 4/8/16 Channel D1 1.5U Standalone DVR User Manual

Page 28

background image

18

Figure 3-2

3.8.3 Alarm Output Port

z

Provide power to peripheral alarm device.

z

To avoid overloading, please read the following relay parameters sheet carefully.

z

RS485 A/B cable is for the A/B cable of the PTZ decoder.

Relay Specification

Model:

JRC-27F

Material of the
touch

Silver

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Rating

Resistance

Load)

Maximum switch currency

1A

Between touches with same
polarity

1000VAC 1minute

Between touches with different
polarity

1000VAC 1minute

Insulation

Between touch and winding

1000VAC 1minute

Surge voltage

Between touches with same
polarity

1500V (10×160us)

Length of open
time

3ms max

Length of close
time

3ms max

Mechanical

50×106 times (3Hz)

Longevity

Electrical

200×103 times (0.5Hz)

Temperature

-40℃ ~+70℃

3.9 RS232

You can connect the DVR with POS or Keyboard through RS232.
With POS system, the DVR can communicate through RS232 and network. For the POS system, the
DVR can integrate the text content and even search the record through the info.
The series DVR also support NKB operation. You can operate the DVR from the keyboard controls
instead of using the control pad on the front panel of the unit.